| Power dissipated single housing with 20 °C |
| Ambient Temperature | 20 °C |
| Reduction Fact | 1 |
| Position for mounting | vertical |
| Dissipated Power | 9.7 W |
| Power dissipated single housing with 30 °C |
| Ambient Temperature | 30 °C |
| Reduction Fact | 0,85 |
| Position for mounting | vertical |
| Dissipated Power | 8.3 W |
| Power dissipated single housing with 40 °C |
| Ambient Temperature | 40 °C |
| Reduction Fact | 0,68 |
| Position for mounting | vertical |
| Dissipated Power | 6.5 W |
| Power dissipated single housing with 50 °C |
| Ambient Temperature | 50 °C |
| Reduction Fact | 0,55 |
| Position for mounting | vertical |
| Dissipated Power | 5.4 W |
| Power dissipated individual housing with 60 °C |
| Ambient Temperature | 60 °C |
| Reduction Fact | 0,4 |
| Position for mounting | vertical |
| Dissipated Power | 3.9 W |
| Vibration test |
| Test Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| frequency | 10 - 150 - 10 Hz |
| Sweep speed | 1 octave/min |
| Amplitude | 0.15 mm (10 Hz ... 58.1 Hz) |
| Acceleration | 2g (58.1 Hz ... 150 Hz) |
| Test duration per axis | 2.5 h |
| Test Directions | X, Y, and Z axes |
| Essay filam. incandescent |
| Test Specification | DIN EN 60695-2-11 (VDE 0471-2-11):2014-11 |
| Temperature | 850 °C |
| Performance Time | 30 sec |
| Heat Resistance/Spherical Pressure Check |
| Test Specification | DIN EN 60695-10-2 (VDE 0471-10-2):2016-01 |
| Temperature | 125 °C |
| Duration of the trial | 1 h |
| Strength | 20 N |
| Mechanical Strength/Descending Drum |
| Test Specification | DIN EN 60068-2-31 (VDE 0468-2-31):2009-04 |
| Drop Height | 50 cm |
| frequency | 50 |
| Crash |
| Test Specification | DIN EN 60068-2-27 (VDE 0468-2-27):2010-02 |
| Shock Type | Semi-sinusoid |
| Acceleration | 35% |
| Duration of the crash | 11 ms |
| Number of collisions per steering | 3 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Testing for substances that are harmful to varnish wetting |
| Test Specification | VW PV 3.10.7:2005-02 |
| Result | Approved Test |
| Protection rating (IP code) |
| Test Specification | DIN EN 60529 (VDE 0470-1):2014-09 |
| Result: Degree of protection IP Code | IP20 |
| Environmental conditions |
| Maximum achievable IP code | IP20 |
| Ambient Temperature (Service) | -40 °C ... 105 °C (depending on dissipation) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 55 °C |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Relative humidity of the air (storage/transport) | 80 % |