PHOENIX CONTACT UBK 2-500 UBK 2-500 2798530 PHOENIX CONTACT Surge protection device View larger
Images are for illustrative purposes only. Please refer to data sheet for details

UBK 2-500 2798530 PHOENIX CONTACT Surge protection device

UBK 2-500

2798530

PHOENIX CONTACT

1 Pcs.

Surge protection device Rail mounting module with sufficient surge protection for two signal conductors. Self-contact ground foot for mounting on NS 32 or NS 35/7.5, housing width: 17.5 mm. Execution: 500 V AC

Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2798530
Packing unit10 pc
Catalog pagePage 54 (TT-2002)
GTIN4017918073800
Weight per Piece (excluding packing)60.010 g
Custom tariff number85363010
Country of originGR (Greece)

Dimensions

Height90 mm
Width17.5 mm
Depth46 mm (incl. DIN rail 7.5 mm)
Horizontal pitch1 Div.

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 mm (amsl (above mean sea level))
Degree of protectionIP20

General

Housing materialPA 6.6
Flammability rating according to UL 94V-2
Colorjet black RAL 9005
Standards for cearances and creepage distancesIEC 60664-1
Mounting typeDIN rail: 35 mm
TypeDIN rail module, one-piece
Direction of actionLine-Earth Ground

Protective circuit

IEC test classificationC2
D1
Nominal voltage UN500 V AC
Maximum continuous voltage UC500 V AC
Rated current2 A
Operating effective current ICat UC≤ 1 µA
Residual current IPE≤ 1 µA
Nominal discharge current In(8/20) µs (line-line)10 kA
Nominal discharge current In(8/20) µs (line-earth)10 kA
Pulse discharge current Iimp(10/350) µs2.5 kA
Output voltage limitation at 1 kV/µs (line-line) static≤ 2.5 kV
≤ 2.7 kV (4 kV (1.2/50) µs)
Output voltage limitation at 1 kV/µs (line-earth) static≤ 1.5 kV
≤ 1.7 kV (4 kV (1.2/50) µs)
Voltage protection level Up(line-line)3.5 kV (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-earth)2.2 kV (C2 - 10 kV / 5 kA)
2.3 kV (Iimp -2.5 kA)
Response time tA(line-line)≤ 100 ns
Response time tA(line-earth)≤ 100 ns
Input attenuation aE, sym.typ. 0 dB (≤ 30 MHz / 50 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ohm systemtyp. 60 MHz
Capacity (line-line)typ. 7 pF
Surge protection fault messagenone
Max. required back-up fuse2 A (gL)
Impulse durability (line-line)C2 - 10 kV/5 kA
Impulse durability (line-earth)C2 - 10 kV/5 kA
D1 - 2.5 kA
Alternating current carrying capacity (line-line)10 A - 1 s
Alternating current carrying capacity (line-earth)10 A - 1 s

Connection data

Connection methodScrew connection
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm
Stripping length8 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section solid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Standards and Regulations

Standards/specificationsIEC 61643-21 2000 + A1:2008
EN 61643-21 2001 + A1:2009

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Classifications


ETIM for 2798530 Earthing, lightning and surge protection (EC000943)
Feature Name Feature Value
Nominal voltage DC (EF008799) 500 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.