PHOENIX CONTACT TRIO3-PS/3AC/24DC/40 TRIO3-PS/3AC/24DC/40 1159045 PHOENIX CONTACT Primary switching power supplies, TRIO POWER, Push-in connectio.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

TRIO3-PS/3AC/24DC/40 1159045 PHOENIX CONTACT Primary switching power supplies, TRIO POWER, Push-in connectio..

TRIO3-PS/3AC/24DC/40

1159045

PHOENIX CONTACT

1 Pcs.

Primary switching power supplies, TRIO POWER, Push-in connection, Rail mounting, input: 3 phase, output: 24 V DC / 40 A, adjustable from 24 V DC ... 28 V DC Primary Switching Power Supplies, TRIO POWER, Push-in Connection, Rail Mount, Input: 3-Phase, Output: 24 VDC / 40 A Primary-switched power supply unit, TRIO POWER, Push-in connection, DIN rail mounting, input: 3-phase, output: 24 V DC / 40 A, adjustable from 24 V DC ... 28 V DC

Automation > DC-power supply

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Input data
AC operation
Supply system configurationStar network (TN, TT, IT (PE))
Nominal input voltage range3x 400 V AC ... 500 V AC
Input voltage range3x 400 V AC ... 500 V AC -20 % ... +10 %
2x 400 V AC ... 500 V AC ±10 %
Typical national grid voltage3x 400 V AC
3x 480 V AC
Voltage type of supply voltageAC
Inrush current< 21 A (25 °C)
Inrush current integral (I2t)< 0.77 A2s
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 21 ms (3x 400 V AC)
typ. 21 ms (3x 480 V AC)
Current consumption3x 1.5 A (3x 400 V AC)
3x 1.2 A (3x 500 V AC)
2x 2.6 A (2x 400 V AC)
2x 2.1 A (2x 500 V AC)
Protective circuitTransient protection; Varistor
Power factor (cos phi)0.94 (3x 480 V AC)
Device mains fuse6.3 A internal (device protection)
Recommended breaker for input protection3x 6 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE< 3.5 mA

Output data
Efficiencytyp. 95.44 % (3x 400 V AC)
typ. 95.71 % (3x 480 V AC)
Nominal output voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)40 A
Dynamic Boost (IDyn.Boost)max. 60 A (5 s)
Short-circuit-proofyes
No-load proofyes
Derating60 °C ... 70 °C
Crest factortyp. 1.549 (3x 400 V AC)
typ. 1.533 (3x 480 V AC)
Output power (PN)960 W
Output power (PDyn. Boost)max. 1440 W (5 s)
Connection in parallelyes, for increasing power and redundancy with diode
Connection in seriesyes, for increased output voltage (observe SELV limit)
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 35 V DC
Residual rippletyp. 13 mVPP(with nominal values)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
< 3 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Rise time≤ 1 s (UOut= 10 % ... 90 %)
Minimum no-load power dissipation< 1.37 W (3x 400 V AC)
Maximum no-load power dissipation< 0.77 W (3x 480 V AC)
Minimum nominal load power dissipation< 45.75 W (3x 400 V AC)
Power loss nominal load max.< 42.52 W (3x 480 V AC)
Integrated fuse protectionno
Signal relay 13/14
Position3.x
Position marking3.1 (13), 3.2 (14)
Switch contact (floating)OptoMOS
Switching voltagemax. 30 V DC (SELV)
Current carrying capacitymax. 100 mA
State conditionUOut> 21 V DC and IOutN (Contact closed)
UOutOut > 0.9 x IN(averaging over 60 s) (Contact open)

Connection data
Input
Position1.x
Connection technology
Position marking1.1 (L1), 1.2 (L2), 1.3 (L3), 1.4 ()
Conductor connection
Connection methodPush-in connection
rigid0.2 mm² ... 4 mm²
1.5 mm² (recommended)
flexible0.2 mm² ... 2.5 mm²
1.5 mm² (recommended)
flexible with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
1.5 mm² (recommended)
flexible with ferrule with plastic sleeve0.25 mm² ... 1.5 mm²
1.5 mm² (recommended)
rigid (AWG)24 ... 12 (Cu)
16 (recommended)
Stripping length10 mm (rigid/flexible)
8 mm (Ferrule)
Output
Position2.x
Connection technology
Position marking2.1, 2.2 (+), 2.3, 2.4, 2.5 (-)
Conductor connection
Connection methodPush-in connection
rigid0.75 mm² ... 16 mm²
10 mm² (recommended)
flexible0.75 mm² ... 16 mm²
10 mm² (recommended)
flexible with ferrule without plastic sleeve0.75 mm² ... 16 mm²
10 mm² (recommended)
flexible with ferrule with plastic sleeve0.75 mm² ... 10 mm²
10 mm² (recommended)
rigid (AWG)20 ... 4 (Cu)
8 (recommended)
Stripping length18 mm (rigid/flexible)
18 mm (Ferrule)
Signal
Position3.x
Connection technology
Position marking3.1 (13), 3.2 (14)
Conductor connection
Connection methodPush-in connection
rigid0.2 mm² ... 1.5 mm²
0.5 mm² (recommended)
flexible0.2 mm² ... 1.5 mm²
0.5 mm² (recommended)
flexible with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (Cu)
0.5 mm² (recommended)
flexible with ferrule with plastic sleeve0.25 mm² ... 0.75 mm²
0.5 mm² (recommended)
rigid (AWG)24 ... 16 (Cu)
20 (recommended)
Stripping length10 mm (rigid/flexible)
8 mm (Ferrule)

Signaling
LED signaling
Types of signalingLED DC OK – signal state operation (UN= 24 V DC, IOut= IN)
FunctionVisual operating state display
Colorred, yellow, green (multicolor LED)
LED offSupply voltage input AC not present (Off)
LED on (green), DC OKUOut> 21 V DC and IOutN (On (green), DC OK)
LED on (yellow), IOut > 90%UOut> 21 V DC and IOut> 0.9 x IN(On (yellow), IOut> 90% )
LED on (red), ISHORTUOutOut > 0.9 x IN(On (red), ISHORT)
LED on (flashing red) OVPUOUT> OVP (Over voltage protection) (On (flashing red))

Electrical properties
Number of phases3.00
Insulation voltage input/output4 kV AC (type test)
4 kV AC (routine test)

Product properties
Product typePower supply
Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 1200000 h (25 °C)
> 660000 h (40 °C)
> 265000 h (60 °C)
Environmental protection directiveRoHS Directive 2011/65/EU
WEEE
Reach
Insulation characteristics
Protection classI
Degree of pollution2

Dimensions
Item dimensions
Width90 mm
Height135 mm
Depth167 mm
160 mm (Device depth (DIN rail mounting))
Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting
Mounting typeDIN rail mounting
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically
Mounting positionhorizontal DIN rail NS 35, EN 60715

Material specifications
Flammability rating according to UL 94V0 (Housing, terminal blocks)
Hood versionPolycarbonate
Side element versionAluminum

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock (operation)18 ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (operation)10 Hz ... 50 Hz, amplitude ±0.2 mm (IEC 60068-2-6)
50 Hz to 150 Hz, 2.3 g, 90 min.

Standards and regulations
Overvoltage category
EN 61010-1III (≤ 2000 m)
II (≤ 5000 m)
Overvoltage category
EN 61010-2-201III (≤ 2000 m)
II (≤ 5000 m)
Safety of power supply units up to 1100 V (insulation distances)
Standard designationSafety of power supply units up to 1100 V (insulation distances)
Standards/specificationsDIN EN 61558-2-16
Electrical safety
Standard designationElectrical safety
Standards/specificationsIEC 61010-2-201 (SELV)
Electronic equipment for use in power installations
Standard designationEquipping high voltage installations with electronic equipment
Standards/specificationsEN 50178/VDE 0160 (PELV)
Safety for measurement, control, and laboratory equipment
Standard designationSafety for equipment for measurement, control, and laboratory use
Standards/specificationsIEC 61010-1
Protective extra-low voltage
Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Safe isolation
Standard designationSafe isolation
Standards/specificationsIEC 61558-2-16
IEC 61010-2-201
Limitation of harmonic line currents
Standard designationLimitation of harmonic line currents
Standards/specificationsEN 61000-3-2
Mains variation/undervoltage
Standard designationMains variation/undervoltage
Standards/specificationsSEMI F47
EN 61000-4-11

Approvals
UL
IdentificationUL/C-UL Listed UL 61010-1
UL
IdentificationUL/C-UL Listed UL 61010-2-201
ANSI/UL 121201
IdentificationPROCESS CONTROL EQUIPEMENT FOR HAZARDOUS LOCATIONS
(EN)  This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Locations, or non-hazardous locations only.
(FR)  Cet appareil convient uniquement pour une utilisation en atmosphères explosibles de classe I, division 2, groupes A, B, C et D ou en atmosphères non explosibles.
(EN)  WARNING: Explosion Hazard - Do not connect or disconnect equipment unless power has been switched off or the area is known to be non-hazardous.
(FR)  AVERTISSEMENT : risque d'explosion - ne pas connecter ou déconnecter les équipements sauf si l'alimentation a été coupée ou si la zone est réputée non dangereuse.
(EN)  If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
(FR)  Si l'équipement est utilisé d'une manière non spécifiée par le fabricant, la protection fournie par cet équipement peut être altérée.
(EN)  This equipement must be installed in a suitable, tool secured/key locked enclosure.
(FR)  Cet équipement doit être installé dans un boîtier approprié, verrouillé par une clé ou dont l'ouverture nécessite l'utilisation d'un outil.

EMC data
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
Noise immunityImmunity in accordance with EN 61000-6-1 (residential), EN 61000-6-2 (industrial)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
EN 61000-6-3 (Class B)
Noise emissionEN 55016
EN 61000-6-3 (Class B)
Harmonic currents
Standards/regulationsEN 61000-3-2
EN 61000-3-2 (Class A)
Frequency range0 kHz ... 2 kHz
Flicker
Standards/regulationsEN 61000-3-3
EN 61000-3-3
Frequency range0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion B
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Inputasymmetrical 2 kV (Test Level 3)
Outputasymmetrical 2 kV (Test Level 3)
Signalasymmetrical 1 kV (Test Level 3)
CommentsCriterion A
Surge voltage load (surge)
Standards/regulationsEN 61000-4-5
Inputsymmetrical 2 kV (Test Level 4)
asymmetrical 4 kV (Test Level 4)
Outputsymmetrical 1 kV (Test Level 3)
asymmetrical 2 kV (Test Level 3)
Signalasymmetrical 1 kV (Test Level 2)
CommentsCriterion A
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
I/O/Sasymmetrical
Frequency range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)
Voltage dips
Standards/regulationsEN 61000-4-11
Voltage480 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 periods
Additional textClass 3
CommentsCriterion A
Voltage dip40 %
Number of periods10 periods
Additional textClass 3
CommentsCriterion B
Voltage dip0 %
Number of periods1 period
Additional textClass 3
CommentsCriterion A
Criteria
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.