View larger
TRIO-UPS-2G/3AC/24DC/20
2906367
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2906367 |
|---|---|
| Packing unit | 1 pc |
| GTIN | 4055626068053 |
| Weight per Piece (excluding packing) | 2,007.000 g |
| Custom tariff number | 85044030 |
| Country of origin | CN (China) |
| Width | 88 mm |
|---|---|
| Height | 130 mm |
| Depth | 160 mm |
| Width with alternative assembly | 160 mm |
| Height with alternative assembly | 130 mm |
| Depth with alternative assembly | 88 mm |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (At +25°C, non-condensing) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Degree of pollution | 2 |
| Installation height | ≤ 4000 m (> 2000 m, observe derating) |
| Inrush current limiting/I²t | < 0.76 A2s |
|---|---|
| Mains buffering | ≥ 25 ms (400 V AC) |
| Typical response time | 200 ms |
| Input fuse, integrated | 6.3 A (slow-blow, internal) |
| Nominal output voltage | 24 V DC |
|---|---|
| Setting range of the output voltage (USet) | 24 V DC ... 28 V DC (> 24 V constant capacity) |
| Nominal output current (IN) | 20 A |
| Dynamic Boost (IDyn.Boost) | 30 A |
| Derating | > 60 °C (2.5%/K of POutnom.) |
| Control deviation | < 0.3 % (Static load change 10 % ... 90 %) |
| Maximum power dissipation in no-load condition | < 3.6 W (400 V AC) |
| Efficiency | typ. 93 % (400 V AC) |
| typ. 92 % (480 V AC) | |
| typ. 94 % (Battery operation) | |
| Residual ripple | < 20 mV |
| Connection in parallel | yes, with diode module uncoupled |
| Surge protection against internal surge voltages | < 30 V DC |
| Feedback resistance | ≤ 35 V DC |
| Net weight | 1.71 kg |
|---|---|
| Insulation voltage input/output | 4 kV AC (type test) |
| 2 kV AC (routine test) | |
| Protection class | I |
| MTBF (IEC 61709, SN 29500) | > 1108720 h (400 V AC, at 25°C) |
| > 680194 h (400 V AC, at 40°C) | |
| > 323816 h (400 V AC, at 60°C) | |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 10 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 6 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 15 mm |
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 4 kV (Test Level 2) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 1 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-6 |
| Frequency range | 0.15 MHz ... 80 MHz |
| Voltage | 10 V (Test Level 3) |
| Conducted noise emission | EN 61000-6-4 (Class A) |
| Standards/regulations | EN 61000-4-12 |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Standard - power supply devices for low voltage with DC output | EN 61204-3 |
| Standard – Safety extra-low voltage | IEC 61010 (SELV) / (PELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| UL approvals | UL Listed UL 61010 |
| UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C | |
| Shock | 30g, 18 ms according to IEC 60068-2-27 |
| Vibration (operation) | in accordance with IEC 60068-2-6 |
| Overvoltage category (EN 61010-1) | II |
| Feature Name | Feature Value |
|---|---|
| Input voltage (EF003840) | 320 V |
| Output voltage (EF003933) | 24 V |
| USB interface (EF002039) | No |
| With communication interface RS-232 (EF007312) | No |
| SNMP (EF005284) | No |
| Voltage type (EF000187) | AC |
| Height (EF000040) | 130 mm |
| Width (EF000008) | 88 mm |
| Depth (EF000049) | 160 mm |
| Weight (EF000167) | 1.733 kg |
| Input connection (EF009726) | Other |