| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| Voltage type of supply voltage | AC |
| Inrush current | < 10 A |
| Inrush current integral (I2t) | < 0.4 A2s |
| Frequency range (fN) | 50 Hz ... 60 Hz (±10 %) |
| Mains buffering time | ≥ 20 ms (120 V AC) |
| Switch-on time | typ. 200 ms |
| Typical current consumption | 6.4 A (100 V AC) |
| Input fuse | 10 A (slow-blow, internal) |
| Signal Bat.-Start | |
| Connection labeling | 3.6 |
| Signalization designation | Bat.-Start |
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 200 kΩ between Bat.-Start and SGnd) |
| Signal Remote | |
| Connection labeling | 3.5 |
| Signalization designation | Remote |
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 35 kΩ between Remote and SGnd) |
| Efficiency | typ. 88 % (100 V AC) |
| typ. 92 % (240 V AC) | |
| typ. (Battery operation) | |
| Derating | > 60 °C (2.5%/K of POutnom.) |
| Crest factor | 1.57 (120 V AC) |
| 1.58 (230 V AC) | |
| Switch-over time | < 3 ms |
| UPS connection in parallel | yes, with diode module uncoupled |
| UPS connection in series | no |
| Energy storage device connection in parallel | yes |
| Feedback voltage resistance | ≤ 35 V DC |
| Protection against overvoltage at the output (OVP) | < 30 V DC |
| Residual ripple | < 20 mV |
| Control deviation | < 0.4 % (change in load, static 10 % ... 90 %) |
| < 2.9 % (Dynamic load change 10 % ... 90 %, 10 Hz) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Rise time | < 34 ms |
| Permissible backup fuse | B16 |
| Mains operation | |
| Output voltage | 24 V DC |
| Output voltage range | 24 V DC ... 28 V DC (> 24 V constant capacity) |
| Output current IN | 20 A |
| Dynamic Boost (IDyn.Boost) | 30 A |
| Maximum no-load power dissipation | < 4 W (230 V AC) |
| Power loss nominal load max. | < 50 W (230 V AC) |
| Battery operation | |
| Output voltage | UBAT-0.1 V DC |
| Output voltage range | 18 V DC ... 30 V DC |
| Output current IN | 20 A |
| Signal Alarm | |
| Connection labeling | 3.2 |
| Signalization designation | Alarm |
| Type of signaling | LED red |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | red |
| Signal Battery mode | |
| Connection labeling | 3.3 |
| Signalization designation | Battery mode |
| Type of signaling | Yellow LED |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | yellow |
| Signal DC OK | |
| Connection labeling | 3.1 |
| Signalization designation | DC OK |
| Type of signaling | Green LED |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | green |
| Signal Ready | |
| Connection labeling | 3.4 |
| Signalization designation | Ready |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| Nominal voltage UN | 24 V DC |
| End-of-charge voltage | max. 30 V DC |
| Charging current (Configurable) | 0.2 A ... 3 A (-25 °C ... 40 °C) |
| Charging current (Reduced) | 3 A ... 0 A (40 °C ... 65 °C) |
| Charging current (Preset) | 2.1 A (-25 °C ... 40 °C) |
| Charging current () | 3 A |
| Nominal capacity range | 4 Ah ... 40 Ah |
| Battery technology | VRLA-AGM |
| Charge characteristic curve | IU0U |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 1 mm² ... 4 mm² |
| flexible | 1 mm² ... 2.5 mm² |
| flexible with ferrule without plastic sleeve | 1 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve | 1 mm² ... 1.5 mm² |
| rigid (AWG) | 16 ... 12 |
| Stripping length | 10 mm |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 2.5 mm² ... 10 mm² |
| flexible | 2.5 mm² ... 6 mm² |
| flexible with ferrule without plastic sleeve | 2.5 mm² ... 6 mm² |
| flexible with ferrule with plastic sleeve | 2.5 mm² ... 4 mm² |
| rigid (AWG) | 12 ... 8 |
| Stripping length | 15 mm |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 0.2 mm² ... 1.5 mm² |
| flexible | 0.2 mm² ... 1.5 mm² |
| flexible with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
| flexible with ferrule with plastic sleeve | 0.2 mm² ... 0.75 mm² |
| rigid (AWG) | 24 ... 16 |
| Stripping length | 8 mm |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 2.5 mm² ... 10 mm² |
| flexible | 2.5 mm² ... 6 mm² |
| flexible with ferrule without plastic sleeve | 2.5 mm² ... 6 mm² |
| flexible with ferrule with plastic sleeve | 2.5 mm² ... 4 mm² |
| rigid (AWG) | 12 ... 8 |
| Stripping length | 15 mm |
| Interface | USB (Modbus/RTU) |
| Number of interfaces | 1 |
| Connection method | MINI-USB Type B |
| Locking | Screw |
| Number of phases | 1.00 |
| Product type | DC UPS with integrated power supply |
| Product family | TRIO UPS |
| MTBF (IEC 61709, SN 29500) | 958219 h (25 °C) |
| 576370 h (40 °C) | |
| 265724 h (60 °C) | |
| Insulation characteristics | |
| Protection class | I |
| Degree of pollution | 2 |
| Item dimensions | |
| Width | 88 mm |
| Height | 130 mm |
| Depth | 160 mm |
| Item dimensions with alternative mounting | |
| Width | 160 mm |
| Height | 130 mm |
| Depth | 88 mm |
| Installation dimensions | |
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
| Mounting type | DIN rail mounting |
| Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
| Hood version | PC |
| Side element version | Aluminum |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -40 °C |
| Maximum altitude | ≤ 4000 m (> 2000 m, observe derating) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (At +25°C, non-condensing) |
| Shock | 30g, 18 ms in accordance with IEC 60068-2-27 |
| Vibration (operation) | in accordance with IEC 60068-2-6 |
| Overvoltage category | |
| EN 61010-1 | II |
| Safety for measurement, control, and laboratory equipment | |
| Standard designation | Safety for equipment for measurement, control, and laboratory use |
| Standards/specifications | IEC 61010-1 |
| Protective extra-low voltage | |
| Standard designation | Protective extra-low voltage |
| Standards/specifications | IEC 61010 (SELV) / (PELV) |
| Safe isolation | |
| Standard designation | Safe isolation |
| Standards/specifications | DIN VDE 0100-410 |
| Low-voltage power supplies, DC output | |
| Standard designation | Low-voltage power supplies, DC output |
| Standards/specifications | EN 61204-3 |
| UL | |
| Identification | UL Listed UL 61010 |
| UL | |
| Identification | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| EMC requirements for noise emission | EN 61000-6-3 |
| EN 61000-6-4 | |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EN 61000-6-2 | |
| Noise immunity | Immunity in accordance with EN 61000-6-2 (industrial) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conducted noise emission | EN 61000-6-3 |
| Noise emission | EN 61000-6-3 |
| Harmonic currents | |
| Standards/regulations | EN 61000-3-2 |
| Flicker | |
| Standards/regulations | EN 61000-3-3 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Contact discharge | 6 kV (Test Level 3) |
| Discharge in air | 8 kV (Test Level 3) |
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 |
| Electromagnetic HF field | |
| Frequency range | 80 MHz ... 6 GHz |
| Test field strength | 10 V/m |
| Frequency range | 1.4 GHz ... 6 GHz |
| Test field strength | 3 V/m |
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 |
| Fast transients (burst) | |
| Input | 4 kV |
| Output | 2 kV |
| Signal | 2 kV |
| Surge voltage load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Input | 2 kV (Test Level 4 - symmetrical) |
| 4 kV (Test Level 4 - asymmetrical) | |
| Output | 1 kV (Test Level 3 - symmetrical) |
| 2 kV (Test Level 3 - asymmetrical) | |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 |
| Conducted interference | |
| Frequency range | 0.15 MHz ... 80 MHz |
| Voltage | 10 V |
| Feature Name | Feature Value |
|---|---|
| Input voltage (EF003840) | 85 V |
| Output voltage (EF003933) | 24 V |
| USB interface (EF002039) | No |
| With communication interface RS-232 (EF007312) | No |
| SNMP (EF005284) | No |
| Voltage type (EF000187) | AC |
| Height (EF000040) | 130 mm |
| Width (EF000008) | 88 mm |
| Depth (EF000049) | 160 mm |
| Weight (EF000167) | 1.697 kg |
| Input connection (EF009726) | Other |