PHOENIX CONTACT TRIO-UPS-2G/1AC/24DC/20 TRIO-UPS-2G/1AC/24DC/20 1105556 PHOENIX CONTACT TRIO UPS UPS with integrated power supply, USB (Modbus/RTU),.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

TRIO-UPS-2G/1AC/24DC/20 1105556 PHOENIX CONTACT TRIO UPS UPS with integrated power supply, USB (Modbus/RTU),..

TRIO-UPS-2G/1AC/24DC/20

1105556

PHOENIX CONTACT

1 Pcs.

TRIO UPS - UPS with integrated power supply, USB (Modbus/RTU), Rail mounting, Push-in connection, input: 1 phase, output: 24 V DC / 20 A TRIO UPS - UPS with integrated power supply for lead-acid AGM energy storage systems 4 Ah - 40 Ah, USB (Modbus/RTU), Rail mounting, Push-in connection, input: 1-phase, output: 24 VDC / 20 A

Automation > UPS
Power Supplies (PS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Input data
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Voltage type of supply voltageAC
Inrush current< 10 A
Inrush current integral (I2t)< 0.4 A2s
Frequency range (fN)50 Hz ... 60 Hz (±10 %)
Mains buffering time≥ 20 ms (120 V AC)
Switch-on timetyp. 200 ms
Typical current consumption6.4 A (100 V AC)
Input fuse10 A (slow-blow, internal)
Signal Bat.-Start
Connection labeling3.6
Signalization designationBat.-Start
Low signalConnection to SGnd with < 2.7 kΩ
High signalOpen (> 200 kΩ between Bat.-Start and SGnd)
Signal Remote
Connection labeling3.5
Signalization designationRemote
Low signalConnection to SGnd with < 2.7 kΩ
High signalOpen (> 35 kΩ between Remote and SGnd)

Output data
Efficiencytyp. 88 % (100 V AC)
typ. 92 % (240 V AC)
typ. (Battery operation)
Derating> 60 °C (2.5%/K of POutnom.)
Crest factor1.57 (120 V AC)
1.58 (230 V AC)
Switch-over time< 3 ms
UPS connection in parallelyes, with diode module uncoupled
UPS connection in seriesno
Energy storage device connection in parallelyes
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)< 30 V DC
Residual ripple< 20 mV
Control deviation< 0.4 % (change in load, static 10 % ... 90 %)
< 2.9 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Rise time< 34 ms
Permissible backup fuseB16
Mains operation
Output voltage24 V DC
Output voltage range24 V DC ... 28 V DC (> 24 V constant capacity)
Output current IN20 A
Dynamic Boost (IDyn.Boost)30 A
Maximum no-load power dissipation< 4 W (230 V AC)
Power loss nominal load max.< 50 W (230 V AC)
Battery operation
Output voltageUBAT-0.1 V DC
Output voltage range18 V DC ... 30 V DC
Output current IN20 A
Signal Alarm
Connection labeling3.2
Signalization designationAlarm
Type of signalingLED red
Switching outputTransistor output, active
Output voltage24 V DC
Continuous load current20 mA
LED status indicatorred
Signal Battery mode
Connection labeling3.3
Signalization designationBattery mode
Type of signalingYellow LED
Switching outputTransistor output, active
Output voltage24 V DC
Continuous load current20 mA
LED status indicatoryellow
Signal DC OK
Connection labeling3.1
Signalization designationDC OK
Type of signalingGreen LED
Switching outputTransistor output, active
Output voltage24 V DC
Continuous load current20 mA
LED status indicatorgreen
Signal Ready
Connection labeling3.4
Signalization designationReady
Switching outputTransistor output, active
Output voltage24 V DC
Continuous load current20 mA

Energy storage
Nominal voltage UN24 V DC
End-of-charge voltagemax. 30 V DC
Charging current (Configurable)0.2 A ... 3 A (-25 °C ... 40 °C)
Charging current (Reduced)3 A ... 0 A (40 °C ... 65 °C)
Charging current (Preset)2.1 A (-25 °C ... 40 °C)
Charging current ()3 A
Nominal capacity range4 Ah ... 40 Ah
Battery technologyVRLA-AGM
Charge characteristic curveIU0U

Connection data
Conductor connection
Connection methodPush-in connection
rigid1 mm² ... 4 mm²
flexible1 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve1 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve1 mm² ... 1.5 mm²
rigid (AWG)16 ... 12
Stripping length10 mm
Conductor connection
Connection methodPush-in connection
rigid2.5 mm² ... 10 mm²
flexible2.5 mm² ... 6 mm²
flexible with ferrule without plastic sleeve2.5 mm² ... 6 mm²
flexible with ferrule with plastic sleeve2.5 mm² ... 4 mm²
rigid (AWG)12 ... 8
Stripping length15 mm
Conductor connection
Connection methodPush-in connection
rigid0.2 mm² ... 1.5 mm²
flexible0.2 mm² ... 1.5 mm²
flexible with ferrule without plastic sleeve0.2 mm² ... 1.5 mm²
flexible with ferrule with plastic sleeve0.2 mm² ... 0.75 mm²
rigid (AWG)24 ... 16
Stripping length8 mm
Conductor connection
Connection methodPush-in connection
rigid2.5 mm² ... 10 mm²
flexible2.5 mm² ... 6 mm²
flexible with ferrule without plastic sleeve2.5 mm² ... 6 mm²
flexible with ferrule with plastic sleeve2.5 mm² ... 4 mm²
rigid (AWG)12 ... 8
Stripping length15 mm

Interfaces
InterfaceUSB (Modbus/RTU)
Number of interfaces1
Connection methodMINI-USB Type B
LockingScrew

Electrical properties
Number of phases1.00

Product properties
Product typeDC UPS with integrated power supply
Product familyTRIO UPS
MTBF (IEC 61709, SN 29500)958219 h (25 °C)
576370 h (40 °C)
265724 h (60 °C)
Insulation characteristics
Protection classI
Degree of pollution2

Dimensions
Item dimensions
Width88 mm
Height130 mm
Depth160 mm
Item dimensions with alternative mounting
Width160 mm
Height130 mm
Depth88 mm
Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Mounting
Mounting typeDIN rail mounting
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm
Mounting positionhorizontal DIN rail NS 35, EN 60715

Material specifications
Flammability rating according to UL 94 (housing / terminal blocks)V0
Hood versionPC
Side element versionAluminum

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 4000 m (> 2000 m, observe derating)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (At +25°C, non-condensing)
Shock30g, 18 ms in accordance with IEC 60068-2-27
Vibration (operation)in accordance with IEC 60068-2-6

Standards and regulations
Overvoltage category
EN 61010-1II
Safety for measurement, control, and laboratory equipment
Standard designationSafety for equipment for measurement, control, and laboratory use
Standards/specificationsIEC 61010-1
Protective extra-low voltage
Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010 (SELV) / (PELV)
Safe isolation
Standard designationSafe isolation
Standards/specificationsDIN VDE 0100-410
Low-voltage power supplies, DC output
Standard designationLow-voltage power supplies, DC output
Standards/specificationsEN 61204-3

Approvals
UL
IdentificationUL Listed UL 61010
UL
IdentificationUL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C

EMC data
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
Noise immunityImmunity in accordance with EN 61000-6-2 (industrial)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 61000-6-3
Noise emissionEN 61000-6-3
Harmonic currents
Standards/regulationsEN 61000-3-2
Flicker
Standards/regulationsEN 61000-3-3
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range80 MHz ... 6 GHz
Test field strength10 V/m
Frequency range1.4 GHz ... 6 GHz
Test field strength3 V/m
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input4 kV
Output2 kV
Signal2 kV
Surge voltage load (surge)
Standards/regulationsEN 61000-4-5
Input2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
Frequency range0.15 MHz ... 80 MHz
Voltage10 V

ETIM for 1105556 Data networking products (EC000382)
Feature Name Feature Value
Input voltage (EF003840) 85 V
Output voltage (EF003933) 24 V
USB interface (EF002039) No
With communication interface RS-232 (EF007312) No
SNMP (EF005284) No
Voltage type (EF000187) AC
Height (EF000040) 130 mm
Width (EF000008) 88 mm
Depth (EF000049) 160 mm
Weight (EF000167) 1.697 kg
Input connection (EF009726) Other

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.