PHOENIX CONTACT MCR-SL-S-200-U MCR-SL-S-200-U 2813460 PHOENIX CONTACT Current transducers View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MCR-SL-S-200-U 2813460 PHOENIX CONTACT Current transducers

MCR-SL-S-200-U

2813460

PHOENIX CONTACT

1 Pcs.

Current transducers MCR current converter, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0...200 A, output voltage 0... (5) 10 V

Automation > Current value transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeCurrent transducer
Data management status
Article revision03
Insulation characteristics
Overvoltage categoryIII
Pollution degree2

Electrical properties
Maximum power dissipation for nominal condition1 W
Test voltage input/output4.13 kV AC (50 Hz, 60 s)
Step response (10-90%)< 340 ms
Maximum temperature coefficient< 0.035 %/K
Maximum transmission error< 1 % (of final value)
Rated insulation voltage300 V AC (to earth)
Supply
Nominal supply voltage24 V DC
Supply voltage range20 V DC ... 30 V DC
Max. current consumption< 30 mA

Input data
Signal
Configurable/programmableYes
Current input signal0 A ... 200 A
Measurement
Input current range0 A AC ... 100 A AC
0 A AC ... 150 A AC
0 A AC ... 200 A AC
Setting range for min. input current0 A AC ... 100 A AC
Setting range for max. input current0 A AC ... 200 A AC
Overload capacityDepending on laid conductor
Surge strengthDepending on through connected conductor
Frequency measuring range30 Hz ... 6000 Hz
Curve typeSinusoidal and non-sinusoidal
Operate threshold1 % (of final value)

Output data
Signal: Voltage
Voltage output signal0 V ... 5 V
0 V ... 10 V
Max. voltage output signal(0 V ... 10 V) 14 V, (0 V ... 5 V) 7 V
Load/output load voltage output≥ 10 kΩ

Connection data
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm (4,4 ... 5,31 lbf-in.)
Connection methodThrough connection

Dimensions
Item dimensions
Width55 mm
Height85 mm
Depth70.5 mm
Circular conductor
Diameter≤ 18.5 mm

Material specifications
Colorgreen (RAL 6021)
Housing materialPolyamide PA non-reinforced

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-20 °C ... 60 °C

Approvals
CE
CertificateCE-compliant
UKCA
CertificateUKCA-compliant
UL, USA/Canada
IdentificationUL/C-UL Listed UL 508
Class I, Div. 2, Groups A, B, C, D T4A
Class I, Zone 2, Group IIC T4A
Or Non-Hazardous Locations only

Mounting
Mounting typeDIN rail mounting
Mounting positionany

ETIM for 2813460 Sensors (EC002475)
Feature Name Feature Value
Initial value measuring range current (EF008198) 0 A
End value measuring range current (EF008266) 200 A
Type of analogy output (EF003958) Other
Integrated configuration function (EF003064) Yes
With switching output (EF005225) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.