PHOENIX CONTACT MCR-S10-50-UI-DCI-NC MCR-S10-50-UI-DCI-NC 2814728 PHOENIX CONTACT Current transducers View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MCR-S10-50-UI-DCI-NC 2814728 PHOENIX CONTACT Current transducers

MCR-S10-50-UI-DCI-NC

2814728

PHOENIX CONTACT

1 Pcs.

Current transducers Programmable and configurable MCR current converter for measuring direct, alternating and distorted currents, input current 0...10 to 0...50 A, not configured

Automation > Current value transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2814728
Packing unit1 pc
Catalog pagePage 243 (C-5-2017)
GTIN4017918169305
Weight per Piece (excluding packing)119.480 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude< 2000 m

Input data

InputCurrent measuring input
Configurable/programmableYes, unconfigured
Input current range0 A ... 55 A (AC/DC)
Operate threshold0.8 % (of measuring range nominal value 50 A)
Setting range for min. input current0 A ... 9.5 A
Setting range for max. input current0 A ... 55 A
Impulse formAC, DC or distorted currents
Overload capacityDepending on through connected conductor
Surge strengthDepending on through connected conductor
Frequency measuring range15 Hz ... 400 Hz
Connection methodThrough connection, diameter 10.5 mm

Output data

Output nameVoltage output / current output
Configurable/programmableYes, unconfigured
Voltage output signal0 V ... 10 V
5 V ... 1 V
5 V ... -5 V
2 V ... 10 V
-10 V ... 10 V
0 V ... 5 V
1 V ... 5 V
-5 V ... 5 V
10 V ... 0 V
10 V ... 2 V
10 V ... -10 V
5 V ... 0 V
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Load/output load voltage output> 10 kΩ
Load/output load current output< 500 Ω

Switching output

Output nameNo switching output

Power supply

Supply voltage range20 V DC ... 30 V DC
Max. current consumption< 40 mA (without load)

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length8 mm
Screw threadM3

General

Maximum transmission error< 0.5 % (of nominal range value under nominal conditions)
Temperature coefficient, typical< 0.025 %/K
Step response (10-90%)330 ms (with AC)
40 ms (with DC)
Status displayGreen LED
Overvoltage categoryIII
Degree of pollution2
Rated insulation voltage300 V AC (to earth)
Test voltage input/output4 kV (50 Hz, 1 min.)
Test voltage input/power supply4 kV (50 Hz, 1 min.)
Test voltage output/power supply500 V (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Colorgreen
Housing materialPolyamide PA non-reinforced
Mounting positionany
ConformanceCE-compliant
UL, USA/CanadaClass I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2
Connection in acc. with standardCUL
Low Voltage DirectiveConformance with Low Voltage Directive
ConformanceCE-compliant
UL, USA/CanadaClass I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X
Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.