View larger
TC-XC96-DO32-EX-HIMAX01
2908752
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Product type | Module carrier |
| Data management status | |
| Article revision | 04 |
| Insulation characteristics: Air clearances and creepage distances | |
| Insulation | Functional insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Max. permissible current | 0.5 A (Signal/channel) |
| Nominal voltage UN | < 50 V DC (Per signal/channel) |
| Air clearances and creepage distances | |
| Rated insulation voltage | 30 V |
| Rated surge voltage | 0.5 kV |
| Supported controller HIMA HIMax | |
| Suitable I/O card | X-DO 32 01 |
| Number of connections | 1 |
| Controller level | |
| Connection in acc. with standard | IEC 60603-2 |
| Connection method | Pin strip |
| Type | C |
| Number of connections | 1 |
| Number of positions | 96 |
| Width | 448 mm |
| Height | 170 mm |
| Depth | 159.5 mm |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Shock | 15g, according to IEC 60068-2-27 |
| Vibration (operation) | 2g, according to IEC 60068-2-6 |
| ATEX | |
| Identification | II 3 G Ex ec IIC T4 Gc X |
| UKCA Ex (UKEX) | |
| Identification | II 3 G Ex ec IIC T4 Gc |
| Certificate | PxCIF21UKEX2908752X |
| UL, USA/Canada | |
| Identification | UL 61010 Listed |
| Class I, Div. 2, Groups A, B, C, D T4 | |
| Class I, Zone 2, Group IIC | |
| Air clearances and creepage distances | |
| Standards/regulations | EN 60664-1 |
| Directive 2014/35/EU (EMV) | |
| Standards/regulations | EN 6100-6-2 |
| EN 6100-6-4 | |
| Directive 2014/34/EU (ATEX) | |
| Standards/regulations | EN 60079-0 |
| EN 60079-7 | |
| EN 60079-11 | |
| Mounting type | DIN rail mounting |
| Assembly note | With end bracket |
| Mounting position | vertical, horizontal |
| Feature Name | Feature Value |
|---|---|
| Number of poles (EF001391) | 96 |
| Rated voltage (EF000228) | 50 V |
| Rated current (EF000227) | 0.5 A |
| Depth (EF000049) | 159.5 mm |
| Width (EF000008) | 448 mm |
| Height (EF000040) | 170 mm |
| Mounting method (EF000003) | DIN rail (top hat rail) 35 mm |