PHOENIX CONTACT TC-XC96-AI32-EX-PRS-HIMAX01 TC-XC96-AI32-EX-PRS-HIMAX01 2908746 PHOENIX CONTACT Termination Carrier for redundantly connecting 32 MACX A.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

TC-XC96-AI32-EX-PRS-HIMAX01 2908746 PHOENIX CONTACT Termination Carrier for redundantly connecting 32 MACX A..

TC-XC96-AI32-EX-PRS-HIMAX01

2908746

PHOENIX CONTACT

1 Pcs.

Termination Carrier for redundantly connecting 32 MACX Analog Ex i signal conditioners to analog input cards of the HIMA HIMax controller, via one C96 connector, 96-pos. Suitable for the HIMax X-AI 32 01 card, with HART multiplexer connection Termination Carrier for the redundant connection of 32 MACX Analog Ex-i separation amplifiers to analog input cards of the HIMA-HIMax control system, via a C96, 96-pole connector. Suitable for HIMax X-AI 32 01 card, with HART multiplexer connection

Automation > Interface module
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2908746
Packing unit1
GTIN4055626327709
Custom tariff number85366990

Drawings



Block diagram

Block diagram

Back to top

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Back to top

General

Nominal voltage UN< 50 V DC (Per signal/channel)
Max. permissible current1 A (Signal/channel)
Back to top

Supply

DesignationDevice supply
Input voltage24 V DC
Input voltage range19.2 V DC ... 30 V DC
Input current≤ 2 A
Redundant supplyyes, decoupled from diodes
Polarization and surge protectionYes
Output nameSwitching output
Contact type1 N/C contact (alarm = open)
Maximum switching voltage30 V DC (2 A)
Fuse2x 3.15 A Slow-blow (exchangeable)
Status display2x green LEDs (PWR1 and PWR2)
Back to top

Connection 1

Connection namePower supply
Connection methodScrew connection
Stripping length7 mm
Number of connections1
Number of positions6
Conductor cross section solid0.75 mm² ... 2.5 mm²
Conductor cross section flexible0.75 mm² ... 2.5 mm²
Conductor cross section AWG18 ... 14
Back to top

Connection 2

Connection nameController level
Connection in acc. with standardIEC 60603-2
Connection methodPin strip
TypeC
Number of connections1
Number of positions96
Back to top

Connection 3

Connection methodIDC/FLK pin strip
Number of connections1
Number of positions14
Back to top

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Shock15g, according to IEC 60068-2-27
Vibration (operation)2g, according to IEC 60068-2-6
Back to top

Dimensions

Width448 mm
Height170 mm
Depth160 mm
Back to top

Standards and Regulations

DesignationAir clearances and creepage distances
Standards/regulationsDIN EN 50178
Rated insulation voltage30 V
Rated surge voltage0.5 kV
InsulationBasic insulation
Pollution degree2
Overvoltage categoryII
DesignationDirective 2014/35/EU (EMV)
Standards/regulationsEN 6100-6-2
EN 6100-6-4
DesignationDirective 2014/34/EU (ATEX)
Standards/regulationsEN 60079-0
EN 60079-7
EN 60079-11
Shock15g, according to IEC 60068-2-27
Vibration (operation)2g, according to IEC 60068-2-6
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Articles in set

Power and error message module TC-MACX-MCR-PTB 2904673

ksbskyqkpm.jpeg

Power and fault signaling module with screw connection, only for use on the Termination Carrier, excluding corresponding DIN rail bus connector

Cable set TC-C-PTB3-SC-SET1 2905216

evkmpfamgn.jpeg

Cable set for TC-MACX-MCR-PTB power and fault signaling module (Order No. 2904673), for use on the Termination Carrier for signal conditioners from the MACX Analog Ex series.

Cable set TC-C-MAX2-SC-31320000 2902425

jwkhgupkxe.jpeg

Cable set for signal transmission on the Termination Carrier for modules from the MACX Analog Ex series. Connection of terminal points 3.1 and 3.2 (signal transmission) to the signal PCB.

DIN rail bus connectors ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561

nlqccldbew.jpeg

DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.

DIN rail bus connectors ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728

cdayqasqny.jpeg

DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.

Back to top

Classifications

eCl@ss

eCl@ss 4.027250313
eCl@ss 4.127250313
eCl@ss 5.027250313
eCl@ss 5.127250313
eCl@ss 7.027141152
eCl@ss 8.027141152
eCl@ss 9.027141152
Back to top

ETIM

ETIM 4.0EC002780
ETIM 5.0EC002780
ETIM 6.0EC002780
ETIM 7.0EC002780
Back to top

ETIM for 2908746 PLC's (EC002780)
Feature Name Feature Value
Number of poles (EF001391) 96
Rated voltage (EF000228) 50 V
Rated current (EF000227) 1 A
Depth (EF000049) 159.5 mm
Width (EF000008) 448 mm
Height (EF000040) 170 mm
Mounting method (EF000003) DIN rail (top hat rail) 35 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.