View larger
TC-D37SUB-AIO16-MP-PS-UNI
2906640
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Product type | Module carrier |
| Data management status | |
| Article revision | 03 |
| Insulation characteristics: Air clearances and creepage distances | |
| Insulation | Basic insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Max. permissible current | 23 mA (Signal/channel) |
| Nominal voltage UN | < 30 V DC (Per signal/channel) |
| Air clearances and creepage distances | |
| Rated insulation voltage | 50 V |
| Rated surge voltage | 0.5 kV |
| Supply | |
| Designation | Power module |
| Note | Power supply via 2902067 MINI MCR-2-PTB-PT power terminal and 2904508 MINI MCR-2-FM-RC-PT fault signaling module |
| Fuse | 2x 2.5 A on PCB, slow-blow (replaceable) |
| Input voltage | 24 V DC |
| Input voltage range | 19.2 V DC ... 30 V DC |
| Input current | ≤ 2 A |
| Redundant supply | yes, decoupled from diodes |
| Polarization and surge protection | Yes |
| Output name | Switching output |
| Contact switching type | 1 N/C contact (alarm = open) |
| Maximum switching voltage | 30 V DC (50 mA) |
| Power supply | |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Number of connections | 1 |
| Number of positions | 6 |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Controller level | |
| Connection method | D-SUB pin strip |
| Number of connections | 1 |
| Number of positions | 37 |
| X11 | |
| Connection method | IDC/FLK pin strip |
| Number of connections | 1 |
| Number of positions | 14 |
| Note | For connecting 16 HART devices to HART multiplexers |
| X12 | |
| Connection method | IDC/FLK pin strip |
| Number of connections | 1 |
| Number of positions | 14 |
| Note | For connecting a second TC-D37SUB-AIO16-MP-PS-UNI (additional 16 HART channels) |
| Status display | 2 x red LED (error) |
| 2x green LEDs (PWR1 and PWR2) |
| Width | 136 mm |
| Height | 170 mm |
| Depth | 159.5 mm |
| Flammability rating according to UL 94 | V0 |
| Ambient conditions | |
| Degree of protection | IP00 |
| Ambient temperature (operation) | -20 °C ... 60 °C (Please observe module specifications) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Shock | 15g, according to IEC 60068-2-27 |
| Vibration (operation) | 2g, according to IEC 60068-2-6 |
| UL, USA/Canada | |
| Identification | UL 61010 Listed |
| Class I, Div. 2, Groups A, B, C, D T4 | |
| Class I, Zone 2, Group IIC | |
| Air clearances and creepage distances | |
| Standards/regulations | EN IEC 60664-1 |
| Mounting type | DIN rail mounting |
| Assembly note | No end clamp |
| Mounting position | vertical, horizontal |
| Feature Name | Feature Value |
|---|---|
| Type of electrical connection, control sided (EF008549) | D-Sub |
| Number of poles (EF001391) | 37 |
| Rated voltage (EF000228) | 30 V |
| Rated current (EF000227) | 0.023 A |
| Depth (EF000049) | 159.5 mm |
| Width (EF000008) | 136 mm |
| Height (EF000040) | 170 mm |
| Mounting method (EF000003) | DIN rail (top hat rail) 35 mm |