PHOENIX CONTACT TAE-TRAB FM-NFN-AP TAE-TRAB FM-NFN-AP 2749628 PHOENIX CONTACT Surge protection device View larger
Images are for illustrative purposes only. Please refer to data sheet for details

TAE-TRAB FM-NFN-AP 2749628 PHOENIX CONTACT Surge protection device

TAE-TRAB FM-NFN-AP

2749628

PHOENIX CONTACT

1 Pcs.

Surge protection device Spray-protected TAE (NFN) connection box with surge protection for analogue and digital telecommunication interfaces (VDSL up to 50 MBit/s, short distances (< 300 m) up to 100 MBit/s)

Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2749628
Packing unit1 pc
Catalog pagePage 165 (C-4-2017)
GTIN4017918108199
Weight per Piece (excluding packing)79.600 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height27 mm
Width65 mm
Depth80 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C
Degree of protectionIP20

General

Housing materialABS
Colorcream white
Standards for cearances and creepage distancesVDE 0110-1
IEC 60664-1
For country-specific use inD
Mounting typeSurface/Wall mounting
TypeSocket for surface mounting
Direction of actionLine-Line & Line-Earth Ground

Protective circuit

IEC test classificationB2
C1
C2
C3
D1
VDE requirement classB2
C1
C2
C3
D1
Nominal voltage UN60 V DC
Maximum continuous voltage UC185 V DC
Rated current450 mA (≤ 40°C)
Operating effective current ICat UC≤ 10 µA
Residual current IPE≤ 6 µA
Nominal discharge current In(8/20) µs (line-line)5 kA
Nominal discharge current In(8/20) µs (line-earth)5 kA
Total discharge current Itotal(8/20) µs10 kA
Total discharge current Itotal(10/350) µs5 kA
Max. discharge current Imax(8/20) µs maximum (line-line)5 kA
Max. discharge current Imax(8/20) µs maximum (line-earth)5 kA
Nominal pulse current Ian (10/1000) µs (line-line)100 A
Nominal pulse current Ian (10/1000) µs (line-earth)100 A
Nominal pulse current Ian (10/700) µs (line-line)150 A
Nominal pulse current Ian (10/700) µs (line-earth)150 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 250 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 450 V
Output voltage limitation at 1 kV/µs (line-line) static≤ 250 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 450 V
Voltage protection level Up(line-line)≤ 250 V (C2 - 10 kV / 5 kA)
≤ 250 V (C1 - 1 kV/500 A)
≤ 250 V (B2 - 4 kV / 100 A)
Voltage protection level Up(line-earth)≤ 500 V (C2 - 10 kV / 5 kA)
≤ 450 V (C1 - 1 kV/500 A)
≤ 400 V (B2 - 4 kV / 100 A)
Response time tA(line-line)≤ 1 ns
Response time tA(line-earth)≤ 100 ns
Input attenuation aE, sym.0.3 dB (≤ 1 MHz / 150 Ω)
0.3 dB (≤ 400 kHz / 600 Ω)
Input attenuation aE, asym.0.3 dB (≤ 400 kHz / 600 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ohm systemtyp. 8 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ohm systemtyp. 2 MHz
Capacity (line-line)typ. 200 pF (f = 1 MHz / VR = 0 V)
Capacity (line-earth)typ. 15 pF (f = 1 MHz / VR = 0 V)
Resistance in series2.2 Ω 10 %
Short-circuit current self-quenching150 mA
Surge protection fault messagenone
Impulse durability (line-line)C2 - 10 kV/5 kA
C1 - 1 kV/500 A
B2 - 4 kV/100 A
Impulse durability (line-earth)C2 - 10 kV/5 kA
C1 - 1 kV/500 A
B2 - 4 kV/100 A
D1 - 2.5 kA
Alternating current carrying capacity (line-earth)5 A - 1 s

Connection data

Connection methodScrew connection & TAE 6
Connection method INScrew terminal blocks
Connection method OUT3x TAE-NFN
Connection technologyScrew connection
Screw threadM3
Tightening torque0.5 Nm
Stripping length6 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section AWG26 ... 16

Connection, equipotential bonding

Connection methodScrew terminal block
Stripping length6 mm
Tightening torque, min0.5 Nm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.16

Standards and Regulations

Standards/regulationsIEC 61643-21
Standards/specificationsDIN EN 61643-21 2002
IEC 61643-21 2000

Classifications


ETIM for 2749628 Earthing, lightning and surge protection (EC000943)
Feature Name Feature Value
Nominal voltage AC (EF008798) 60 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.