Surge protection device Two-level surge protection for three or four potential-free driven signal circuit signals to ground on the IP67 rated spin-on module for sensor heads, 1/2 in. 14 NPT. Tested according to the types of protection in the Ex Ex d/Ex tD/Ex ia IIC/Ex iaD zones. Suitable for use in fieldbus systems according to the FISCO concept (intrinsically safe bus concept), suitable for HART. Two-stage surge protection for three or four signals of floating signal circuits in the screw-on module with IP67 degree of protection for sensor heads, connection ½-inch 14 NPT. Tested in accordance with the following types of protection in Ex areas: Ex d/Ex tD/Ex ia IIC/Ex iaD. Suitable for use in the fieldbus system in accordance with the FISCO concept, HART-compatible. Can be used in safety-related circuits up to SIL 3.

Automation > Combined arrester for data networks/MCR-technology
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeSurge protection for MCR technology
Product familySURGETRAB
IEC test classificationC1
C2
C3
D1
TypeScrew-in module
Number of positions4
Data management status
Article revision08
Insulation characteristics
Overvoltage categoryIII
Pollution degree2

Electrical properties
Nominal voltage UN24 V DC

Connection data
Connection methodIndividual wires

Ex data
Maximum inner capacitance Ci1.65 nF
Max. internal inductance Li1 µH
Max. input current Ii500 mA (T4 / ≤ 75 °C)
500 mA (T5 / ≤ 75 °C)
500 mA (T6 / ≤ 60 °C)
Max. input voltage Ui36 V DC
max. input power Pi3.00 W
Insulation voltage to ground500 V AC
Ambient temperature (operation)-40 °C ... 75 °C (T4)
-40 °C ... 75 °C (T5)
-40 °C ... 60 °C (T6)
Operating temperature range-40 °C ... 100 °C (T4)
-40 °C ... 75 °C (T5)
-40 °C ... 60 °C (T6)
Max. surface temperature135 °C (T4)
100 °C (T5)
85 °C (T6)

Dimensions
Dimensional drawinguqkecwnjvk.jpg
Width28 mm
Height28 mm
Depth79 mm

Material specifications
ColorSteel/stainless steel color
Housing materialStainless steel 1.4404
ASTM 316L

Mechanical properties
Mechanical data
Open side panelNo

Protective circuit
Direction of actionLine-Line & Line-Earth Ground
Maximum continuous voltage UC36 V DC
25 V AC
Operating effective current ICat UC≤ 5 µA
Residual current IPE≤ 2 µA
Nominal discharge current In(8/20) µs (line-line)260 A
Nominal discharge current In(8/20) µs (line-ground)10 kA
Pulse discharge current Iimp(10/350) µs1 kA
Total discharge current Itotal(8/20) µs20 kA
Total discharge current Itotal(10/350) µs2 kA
Nominal pulse current Ian (10/1000) µs (line-line)50 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 130 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 1.1 kV
Output voltage limitation at 1 kV/µs (line-line) static≤ 60 V
Voltage protection level Up(line-line)≤ 65 V (C3 - 10 A)
Voltage protection level Up(line-earth)≤ 1.1 kV (C3 - 100 A)
≤ 1.1 kV (C1 - 1 kV / 500 A)
≤ 1.2 kV (C2 - 10 kV / 5 kA)
Response time tA(line-line)≤ 1 ns
Response time tA(line-earth)≤ 100 ns
Input attenuation aE, sym.typ. 0.1 dB (30 MHz / 50 Ω)
typ. 0.1 dB (6 MHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ω systemtyp. 70 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 70 MHz
Capacity (Core-Core)typ. 20 pF
Capacity (Core-Earth)typ. 5 pF
Surge protection fault messagenone
Impulse durability (line-line)C3 - 25 A
Impulse durability (line-earth)C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
C3 - 100 A
D1 - 1 kA
Alternating current carrying capacity (line-earth)10 A - 1 s

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP67
Ambient temperature (operation)-40 °C ... 80 °C (non-Ex)
Altitude≤ 2000 m (amsl)

Approvals
Conformity/Approvals
ATEX II 1 G Ex ia IIC T4...T6
 II 2 G Ex d IIC T4...T6
 II 1 D Ex iaD 20 IP6x T85 °C...135 °C
 II 2 D Ex tD A21 IP6x T85 °C...135 °C
IECExGa Ex ia IIC T4...T6
Ex d IIC T4...T6
Ex iaD IP6x T85 °C...135 °C
Ex tD A21 IP6x T85 °C...135 °C

Standards and regulations
Air clearances and creepage distances
Standards/regulationsIEC 60664-1 / IEC 60079-11
Standards/specificationsEN 61643-21
NoteA2:2013
Standards/specificationsEN 60079-0
Note2018
Standards/specificationsEN 60079-1
Note2007
Standards/specificationsEN 60079-11
Note2012
Standards/specificationsEN 60079-31
Note2009
Standards/specificationsIEC 60079-0
Note2017
Standards/specificationsIEC 60079-1
Note2007
Standards/specificationsIEC 60079-11
Note2011
Standards/specificationsIEC 60079-31
Note2008

Mounting
Mounting type1/2" NPT

Product Datasheet