PHOENIX CONTACT DT-LAN-CAT.6+ DT-LAN-CAT.6+ 2881007 PHOENIX CONTACT Surge protection device View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DT-LAN-CAT.6+ 2881007 PHOENIX CONTACT Surge protection device

DT-LAN-CAT.6+

2881007

PHOENIX CONTACT

1 Pcs.

Surge protection device Surge protection according to EA class (CAT6A), for Gigabit Ethernet (up to 10 GBit/s), Token Ring, FDDI/CDDI, ISDN, DS1. Suitable for Power over Ethernet (PoE++ / 4PPoE) "Mode A" and "Mode B". RJ45 intermediate connector with separate grounding conductor and grounding interlocking foot for NS 35 rail.

Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2881007
Packing unit1 pc
Catalog pagePage 142 (C-4-2017)
GTIN4046356151900
Weight per Piece (excluding packing)314.100 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height102 mm
Width25 mm
Depth63.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Degree of protectionIP20

General

Housing materialZinc die-cast
Colorsilver/black
Mounting typeConnection-specific attachment plug and DIN rail, 35 mm
TypeAttachment plug for DIN rail mounting
Number of positions8
Direction of actionLine-Line & Line-Ground/Shield

Protective circuit

IEC test classificationB2
C1
C2
C3
D1
Maximum continuous voltage UC(wire-wire)≤ 3.3 V DC (± 60 V DC/PoE+)
Rated current≤ 1.5 A (25 °C)
Operating effective current ICat UC≤ 1 µA
Residual current IPE≤ 400 µA
Nominal discharge current In(8/20) µs (line-line)100 A
Nominal discharge current In(8/20) µs (line-earth)2 kA (per signal pair)
Total discharge current Itotal(8/20) µs10 kA
Nominal pulse current Ian (10/700) µs (line-line)≤ 40 A
Nominal pulse current Ian (10/700) µs (line-earth)≤ 160 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 85 V (PoE)
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 700 V
Output voltage limitation at 1 kV/µs (line-line) static≤ 9 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 700 V
Residual voltage at In(line-line)≤ 15 V
≤ 100 V (PoE)
Voltage protection level Up(line-line)≤ 9 V (B2 - 1 kV / 25 A)
≤ 100 V (B2 - 1 kV / 25 A - PoE)
≤ 12 V (C3 - 20 A)
Voltage protection level Up(line-earth)≤ 900 V (B2 - 4 kV / 100 A)
≤ 700 V (C2 - 4 kV / 2 kA)
≤ 1 kV (C3 - 80 A)
Response time tA(line-line)≤ 1 ns
Response time tA(line-earth)≤ 100 ns
Input attenuation aE, sym.≤ 1 dB (up to100 MHz/direct measuring)
≤ 1 dB (up to 250 MHz/direct measuring)
≤ 3 dB (up to 500 MHz/direct measuring)
Near-end crosstalk attenuation≥ 35 dB (250 MHz/100 Ω/link)
≥ 45 dB (100 MHz / 100 Ω / Link)
≥ 27 dB (500 MHz / 100 Ω / Link)
≥ 39 dB (250 MHz/100 Ω/direct measuring)
Capacity (line-line)typ. 12 pF (f= 1 MHz / VR= 0 V)
Capacity (line-earth)typ. 2 pF (f= 1 MHz / VR= 0 V)
Surge protection fault messagenone
Impulse durability (line-line)B2 - 1 kV / 25 A
C3 - 20 A
Impulse durability (line-earth)B2 - 4 kV/100 A
C2 - 4 kV/2 kA
C3 - 80 A
D1 - 1 kA

Connection data

Connection methodRJ45

Connection, equipotential bonding

Connection methodDIN rail NS35

Standards and Regulations

Standards/specificationsIEC 61643-21 2002
EN 50173-1 2002
ISO/IEC 11801-Am.1 2006

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.