PHOENIX CONTACT CT 10-18FS+F/PE-24 CT 10-18FS+F/PE-24 2807926 PHOENIX CONTACT Surge protection plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CT 10-18FS+F/PE-24 2807926 PHOENIX CONTACT Surge protection plug

CT 10-18FS+F/PE-24

2807926

PHOENIX CONTACT

1 Pcs.

Surge protection plug LSA-PLUS (COMTRAB CT 10) connector with coarse/fine surge protection for 18 signal lines - GND and coarse GND protection - PE. Nominal voltage: 24 V DC. Version: 10 two-wire circuits

Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2807926
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 107 (C-6-2013)
GTIN4017918075408
Weight per Piece (excluding packing)106.510 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height22 mm
Width111 mm
Depth68.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 75 °C
Altitude≤ 2000 mm (amsl (above mean sea level))
Degree of protectionIP20

General

Housing materialPBT
Flammability rating according to UL 94V-0
Colorjet black RAL 9005
Standards for cearances and creepage distancesVDE 0110-1
Mounting typeOn CT-TERMIBLOCK and LSA-PLUS disconnect strip
TypeLSA-PLUS module
Direction of actionLine-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.00

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN24 V DC
24 V AC
Maximum continuous voltage UC40 V DC
28 V AC
Rated current1.5 A AC (75 °C)
350 mA DC (75 °C)
Operating effective current ICat UC≤ 5 µA (18x)
Residual current IPE≤ 1 µA (19x)
Nominal discharge current In(8/20) µs (line-line)119 A (per path)
Nominal discharge current In(8/20) µs (line-earth)5 kA (per path)
Nominal discharge current In(8/20) µs (signalground-earth)5 kA (per path)
Pulse discharge current Iimp(10/350) µs (line-earth)2.5 kA
Pulse discharge current Iimp(10/350) µs (signalground-earth)2.5 kA
Total discharge current Itotal(8/20) µs10 kA
Max. discharge current Imax(8/20) µs maximum (line-line)119 A (per path)
Max. discharge current Imax(8/20) µs maximum (line-earth)5 kA (per path)
Nominal pulse current Ian (10/1000) µs (line-signalground)23 A
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 650 V
Output voltage limitation at 1 kV/µs (line-signalground) spike≤ 70 V
Output voltage limitation at 1 kV/µs (line-signalground) static≤ 60 V
Residual voltage at In(line-earth)≤ 30 V
Residual voltage at In(line-signalground)≤ 85 V
Residual voltage with Ian (10/1000) µs (line-signalground)≤ 65 V
Response time tA (line-signalground)≤ 1 ns
Response time tA(line-earth)≤ 100 ns
Input attenuation aE, asym.typ. 0.1 dB (≤ 2 MHz / 50 Ω)
typ. 0.1 dB (≤ 200 kHz / 150 Ω)
typ. 0.1 dB (≤ 80 kHz / 600 Ω)
Cut-off frequency fg (3 dB), asym. (GND) in 50 Ohm systemtyp. 10 MHz
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm systemtyp. 2.5 MHz
Cut-off frequency fg (3 dB), asym. (GND) in 600 Ohm systemtyp. 650 kHz
Capacity (line-signalground)typ. 1.1 nF (1 MHz)
Surge protection fault messagenone
Impulse durability (line-earth)C2 - 10 kV/5 kA
D1 - 2.5 kA
Impulse durability (line-signalground)C3 - 23 A
Impulse durability (signalground-earth)D1 - 2.5 kA

Connection data

Connection methodcan be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Connection method INCOMTRAB plug-in system
Connection method OUTCOMTRAB plug-in system

Standards and Regulations

Standards/specificationsIEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
EN 61643-21 2001 + A1:2009 + A2:2013

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2807926 Earthing, lightning and surge protection (EC000943)
Feature Name Feature Value
Nominal voltage DC (EF008799) 24 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.