PHOENIX CONTACT SOL-SC-2ST-0-DC-4MPPT-1000EQSE SOL-SC-2ST-0-DC-4MPPT-1000EQSE 1491583 PHOENIX CONTACT String box for photovoltaic installations up to 1000 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SOL-SC-2ST-0-DC-4MPPT-1000EQSE 1491583 PHOENIX CONTACT String box for photovoltaic installations up to 1000 ..

SOL-SC-2ST-0-DC-4MPPT-1000EQSE

1491583

PHOENIX CONTACT

1 Pcs.

String box for photovoltaic installations up to 1000 V DC for the connection of 4x 2 strings. Same number of input and output strings. With surge protection (type 1/2) and cable glands for the inlet and outlet side. Connection of the MPP trackers divided into two boxes. String combiner box for photovoltaic systems up to 1000 V DC for connecting 4x 2 strings. Same number of input and output strings. With surge protection (type 1/2) and cable glands for the input and output side. Connection of the MPP trackers divided between two housings.

Automation > Photovoltaic DC Stringbox
Industry Solutions (IS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeString combiner box (SCB)
Insulation characteristics
Protection classII

Electrical properties
General
MPP voltage UNmax. 1000 V DC
Non-load voltage UOCmax. 1100 V DC
Current per string Imaxmax. 20 A
Total current MPP trackermax. 40 A
Surge protection
EN typeT1
IEC test classificationT1
Protection level Up≤ 3.5 kV
Total discharge current Itotal(10/350) µs5 kA
Total discharge current Itotal(8/20) µs40 kA
Short-circuit current rating ISCPV40 A

Input data
Number of inputs: Strings2 (per MPP tracker)
Number of supported MPP trackers4

Output data
DC
Number of outputs: MPP tracker4
Number of outputs: ±2 (per MPP tracker)

Connection data
DC input
Type of cable entryCable gland
Connection methodPush-in connection
Cable cross section4 mm² ... 6 mm²
External cable diameter3 mm ... 6.5 mm
Protective bonding and protective grounding conductor
Type of cable entryCable gland
Connection methodPush-in connection
Cable cross section2x 16 mm²
External cable diameter2x 6 mm ... 12 mm
DC output
Type of cable entryCable gland
Connection methodPush-in connection
Cable cross section4 mm² ... 6 mm²
External cable diameter3 mm ... 6.5 mm

Dimensions
Housing
Width508 mm
Height180 mm
Depth111 mm

Material specifications
Material HousingPolycarbonate
Material Cover/doorPolycarbonate (transparent)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
Ambient temperature (operation)-20 °C ... 50 °C

Standards and regulations
Standard designationLow-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies
Standards/specificationsEN 61439-2

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.