PHOENIX CONTACT SOL-SC-1ST-0-DC-4MPPT-1100SEC SOL-SC-1ST-0-DC-4MPPT-1100SEC 1455739 PHOENIX CONTACT String box for photovoltaic installations up to 1000 V.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SOL-SC-1ST-0-DC-4MPPT-1100SEC 1455739 PHOENIX CONTACT String box for photovoltaic installations up to 1000 V..

SOL-SC-1ST-0-DC-4MPPT-1100SEC

1455739

PHOENIX CONTACT

1 Pcs.

String box for photovoltaic installations up to 1000 V DC, for the connection of 4x 1 strings. With surge protection (type 1/2), DC load disconnector and cable glands for the input and output side. String combiner box for photovoltaic systems up to 1,000 V DC for connecting 4x 1 string. With surge protection (type 1/2), DC switch disconnector with direct drive, and cable glands for the input and output side.

Automation > Photovoltaic DC Stringbox
Industry Solutions (IS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeString combiner box (SCB)
DesignDC switch disconnector
Insulation characteristics
Protection classII

Electrical properties
General
MPP voltage UNmax. 1000 V DC
Non-load voltage UOCmax. 1100 V DC
Current per string Imaxmax. 32 A
DC switch disconnector
Rated operating current DC-21B32 A
Rated operating current DC-PV132 A
Surge protection
EN typeT1
IEC test classificationT1
Protection level Up≤ 1.8 kV
Total discharge current Itotal(10/350) µs5 kA
Total discharge current Itotal(8/20) µs40 kA
Short-circuit current rating ISCPV32 A

Input data
DC
Number of inputs: Strings1 (per MPP tracker)
Number of supported MPP trackers4

Output data
DC
Number of outputs: MPP tracker4
Number of outputs: ±1 (per MPP tracker)

Connection data
DC input
Type of cable entryCable gland
Connection methodPush-in connection
Cable cross section4 mm² ... 6 mm²
External cable diameter5 mm ... 10 mm
Protective bonding and protective grounding conductor
Type of cable entryCable gland
Connection methodScrew connection
Cable cross section2x 16 mm²
External cable diameter2x 6 mm ... 12 mm
DC output
Type of cable entryCable gland
Connection methodPush-in connection
Cable cross section4 mm² ... 6 mm²
External cable diameter5 mm ... 10 mm

Dimensions
Housing
Width361 mm
Height254 mm
Depth111 mm

Material specifications
Material HousingPolycarbonate
Material Cover/doorPolycarbonate (transparent)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
Ambient temperature (operation)-20 °C ... 45 °C

Standards and regulations
Standard designationLow-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies
Standards/specificationsEN 61439-2

Product Datasheet