PHOENIX CONTACT SOL-SC-1ST-0-DC-1MPPT-1300FS SOL-SC-1ST-0-DC-1MPPT-1300FS 1137053 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SOL-SC-1ST-0-DC-1MPPT-1300FS 1137053 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000..

SOL-SC-1ST-0-DC-1MPPT-1300FS

1137053

PHOENIX CONTACT

1 Pcs.

String combiner box for photovoltaic systems up to 1000 V DC for connecting 1x 1 string. With surge protection (type 1/2), DC fire service switch disconnector with remote access and Push-in connection for the input and output side. String boxes for photovoltaic installations up to 1000 V DC for the connection of 1x 1 string. With surge protection (type 1/2), load disconnector for DC firefighters with remote access and push-in connection for the input and output side.

Automation > Photovoltaic DC Stringbox
Industry Solutions (IS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1137053
Packing unit1
GTIN4063151074302
Custom tariff number85371098

Drawings



Connection diagram

Connection diagram
Schematic application drawing

Connection diagram

Connection diagram
Connection of the emergency switching off operation for the fireman's switch



Circuit diagram

Circuit diagram
Connection of the remote indication contact on the surge protection

Schematic diagram

Schematic diagram
Connection of the PV strings, as well as connection to the inverter



Schematic diagram

Schematic diagram
Connection of the protective grounding conductor

Back to top

System parameter

System voltage1000 V DC (Umax)
Number of string inputs1
Current per string (max.)40 A (Imax)
Number of outputs1
Number of supported MPP trackers1
Switching capacity50 A (1000 V)
Rated operating current at DC-PV140 A
Back to top

Safety equipment

Surge protective deviceT1 / T2
Protection level Up≤ 3.5 kV
Total discharge current Itotal(8/20) µs40 kA
Total discharge current Itotal(10/350) µs5 kA
Back to top

Cable entry

Type of cable entryCable gland
Cable cross section string input2.5 mm² ... 6 mm²
Sealing area string input3 mm ... 6.5 mm
Cable cross section output2.5 mm² ... 6 mm²
Sealing area output3 mm ... 6.5 mm
Cable cross section grounding16 mm² (2x)
Sealing area grounding6 mm ... 12 mm (2x)
Cable cross section emergency stop3x 0.14 mm² ... 2.5 mm² (230 V AC)
2x 0.14 mm² ... 2.5 mm² (Remote indication contact, potential-free, max. 24 V DC)
Sealing area emergency stop6 mm ... 12 mm
Back to top

General data

Material cover/doorPolyester fiberglass reinforced
Degree of protectionIP65
Protection classI
Back to top

Dimensions

Outer dimensions: width, height, depth400 mm x 400 mm x 200 mm (Housing dimensions)
Back to top

Ambient conditions

Ambient temperature (operation)-20 °C ... 40 °C
Back to top

Classifications

eCl@ss

eCl@ss 10.0.127142422
eCl@ss 5.127371890
eCl@ss 7.027142422
eCl@ss 8.027142422
eCl@ss 9.027142422
Back to top

ETIM

ETIM 4.0EC000816
ETIM 5.0EC000268
ETIM 6.0EC000268
ETIM 7.0EC000268
Back to top

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.