PHOENIX CONTACT PSR-SPP-24DC/URML4/3X1/1X2/B PSR-SPP-24DC/URML4/3X1/1X2/B 2903584 PHOENIX CONTACT Extension module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-SPP-24DC/URML4/3X1/1X2/B 2903584 PHOENIX CONTACT Extension module

PSR-SPP-24DC/URML4/3X1/1X2/B

2903584

PHOENIX CONTACT

1 Pcs.

Extension module Contact extension 1 channel or 2 channel for OSSD signals (e.g. light curtain), 3 NO contacts, 1 NC contact, up to cat.4PLe depending on EN@ISO13849, SIL3 depending on EN62061, plug-in push-in terminal, width: 22.5mm 1- or 2-channel contact extension for OSSD signals (e.g., light grid), 3 N/O contacts, 1 N/C contact, up to Cat. 4 PL e in accordance with EN ISO 13849, SIL 3 in accordance with EN IEC 62061, pluggable Push-in terminal block, width: 22.5 mm

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Note on application
Note on applicationOnly for industrial use

Product properties
Product typeSafety relays
Product familyPSRclassic
ApplicationExtension module
Mechanical service lifeapprox. 107cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Data management status
Article revision06
Times
Typical response time125 ms (For Usautostart)
Typical release time10 ms (on demand via the sensor circuit)
Recovery time1 s (following demand of the safety function)

Electrical properties
Maximum power dissipation for nominal condition16.44 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.04 W + 14.4 W)
Nominal operating mode100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage250 V
Rated surge voltage/insulation4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)

Input data
Digital: Logic (S12, S22)
Description of the inputsafety-related
Number of inputs2
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal20.4 V ... 26.4 V
Input current range "0" signal0 mA ... 2 mA
Inrush currentmax. 110 mA (typically with US, Δt = 3 ms)
Filter timemax. 2 ms (Test pulse width low test pulses, at 100 ms test pulse rate)
No brightness test pulses / high test pulses permitted.
Concurrence
Max. permissible overall conductor resistance50 Ω
Protective circuitSuppressor diode
Current consumption38 mA (typical, at 24 V)

Output data
Relay: Enabling current paths (13/14, 23/24, 33/34)
Output description2 N/O contacts each in series, safety-related, floating
Number of outputs3
Contact switching type3 enabling current paths
Contact materialAgSnO2
Switching voltagemin. 10 V
max. 250 V AC/DC
Switching capacitymin. 100 mW
Inrush currentmin. 10 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-15 A (AC15)
6 A (DC13)
Limiting continuous current6 A (Observe derating and load limit curve)
Sq. Total current72 A2(observe derating)
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106cycles
Output fuse10 A gL/gG
4 A gL/gG (for low-demand applications)
Relay: Signaling current path (41/42)
Output description2 N/C contacts parallel, non-safety-related, floating
Number of outputs1
Contact switching type1 signaling current path
Contact materialAgSnO2
Switching voltagemin. 10 V AC/DC
max. 250 V AC/DC
Switching capacitymin. 100 mW
Inrush currentmin. 10 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-11.5 A (AC15)
2 A (DC13)
Limiting continuous current6 A
Sq. Total current36 A2
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106cycles
Output fuse6 A gL/gG

Connection data
Connection technology
pluggableyes
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG24 ... 16
Stripping length8 mm

Signaling
Status display2 x LED (green)

Dimensions
Width22.5 mm
Height117.5 mm
Depth114.5 mm

Material specifications
Color (Housing)yellow (RAL 1018)
Housing materialPolyamide

Characteristics
Safety data
Stop category0
Safety data: EN ISO 13849
Category4
Performance level (PL)e (5 A DC13; 5 A AC15; 8760 switching cycles/year)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL)3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL)3
Safety data: EN IEC 62061
Safety Integrity Level (SIL)3

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Ambient temperature (operation)-20 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (operation)10 Hz ... 150 Hz, amplitude 0.15 mm, 2g

Approvals
CE
IdentificationCE-compliant

Standards and regulations
Air clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 60947-1

Mounting
Mounting typeDIN rail mounting
Mounting positionvertical or horizontal

ETIM for 2903584 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Expansion device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Spring clamp connection
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) No
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With muting function (EF004057) No
With feedback circuit (EF003343) No
Release-delay (EF001129) 0.125 s
Number of outputs, safety related, undelayed, with contact (EF003344) 0
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 0
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) No
Width (EF000008) 22.5 mm
Height (EF000040) 117.5 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.