PHOENIX CONTACT PACT RCP-4000A-UIRO-PT-D190 PACT RCP-4000A-UIRO-PT-D190 2906236 PHOENIX CONTACT Current transformer View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PACT RCP-4000A-UIRO-PT-D190 2906236 PHOENIX CONTACT Current transformer

PACT RCP-4000A-UIRO-PT-D190

2906236

PHOENIX CONTACT

1 Pcs.

Current transformer The set consists of a 4-way separation amplifier with push-in connection technology and a Rogowski coil with a length of 600 mm and a diameter of 190 mm for AC current measurement on busbars and high-voltage lines. On the output side, the separation amplifier outputs 8 different standard signals and has a switching output.

Automation > Current transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2906236
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 237 (C-5-2017)
GTIN4055626048345
Weight per Piece (excluding packing)420.100 g
Custom tariff number85437090
Country of originDE (Germany)

Measuring transducer supply

Nominal supply voltage24 V DC
Nominal supply voltage range9.6 V DC
Power consumption≤ 1 W (at IOUT= 20 mA, 9.6 V DC, 600 Ω load)

Measuring coil input data

Frequency measuring range40 Hz ... 20000 Hz
Position error< 1 %
< 1.5 % (the measuring coil is at an angle to the live connector.)
Linearity error0.1 %

Measuring transducer input data

Measuring ranges (current)100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
Configurable/programmableVia DIP switches

Measuring transducer signal input

Input signal (at 50 Hz)100 mV (1000 A)
Input impedance> 100 kΩ

Measuring coil signal output

Output signal (at 50 Hz)100 mV (no load, at 1,000 A)
Output voltage (in no-load operation)VOUT= M * dI/dt
Output voltage (sinusoidal, in no-load operation)100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))

Measuring transducer signal output

Current output signal0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
0 mA ... 10 mA (via DIP switch)
2 mA ... 10 mA (via DIP switch)
0 mA ... 21 mA (can be set via software)
Voltage output signal0 V ... 10 V (via DIP switch)
2 V ... 10 V (via DIP switch)
0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 10.5 V (can be set via software)
Load/output load current output≤ 600 Ω (at 20 mA)

General data, measuring coil

Length of measuring coil600 mm
Diameter of measuring coil8.3 mm ±0.2 mm
Length of signal cable3000 mm
Conductor structure signal line2x 0.22 mm (Signal (tinned))
1x 0.22 mm (Shielding (tinned))
Coil materialElastollan
Housing materialPC
Insulationdouble insulation
Rated insulation voltage1000 V AC (rms CAT III)
600 V AC (rms CAT IV)
Test voltage10.45 kV (DC / 1 min.)
Basic accuracy
UL, USA/CanadaUL 61010 Recognized

General data for measuring transducer

Maximum transmission error≤ 0.5 % (From the range end value)
Frequency range45 Hz ... 65 Hz
Housing materialPBT
Test voltage3 kV (50 Hz, 1 min.)
UL, USA/CanadaUL 508 Listed

General data

Standards/regulationsIEC 61010-1
IEC 61010-2-032
Degree of pollution2
Overvoltage categoryII
Typical measuring error< 1 %

Connection data

Connection nameMeasuring transducer side
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.12
Screw threadM3
Connection methodPush-in connection
Stripping length10 mm

Dimensions

Width6.20 mm
Height110.50 mm
Depth120.50 mm

Ambient conditions

Ambient temperature (operation)-30 °C ... 80 °C (Measuring coil)
-40 °C ... 70 °C (Measuring transducer)
Ambient temperature (storage/transport)-40 °C ... 80 °C (Measuring coil)
-40 °C ... 85 °C (Measuring transducer)
Maximum altitude> 4000 m
Measuring coil degree of protectionIP67 (not assessed by UL)
Measuring transducer degree of protectionIP20

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise emissionEN 61000-6-4
Standards/regulationsIEC 61010-1
IEC 61010-2-032
Rated insulation voltage300 V
Degree of pollution2
Overvoltage categoryII
Electrical isolationReinforced insulation in accordance with IEC 61010-1
ConformanceCE-compliant

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.