PHOENIX CONTACT SAC-3P-MS/ 2,0-28R SCO RAIL SAC-3P-MS/ 2,0-28R SCO RAIL 1407296 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-3P-MS/ 2,0-28R SCO RAIL 1407296 PHOENIX CONTACT Sensor/actuator cable

SAC-3P-MS/ 2,0-28R SCO RAIL

1407296

PHOENIX CONTACT

1 Pcs.

Sensor/actuator cable Sensor/actuator cable, 3-pole halogen-free, shielded, M12 straight connector, coding: A SPEEDCON, to free cable end, cable length: 2 m, For railway applications

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1407296
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 130 (C-4-2013)
GTIN4046356774130
Weight per Piece (excluding packing)117.200 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable2 m

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C (Plug / socket)
Degree of protectionIP65

General

NoteFurther products with variable cable type and variable cable length can be found in the accessories section
Rated current at 40°C4 A
Rated voltage48 V AC
60 V DC
Number of positions3
Color handle areablack
Insulation resistance≥ 100 MΩ
CodingA - standard
Standards/regulationsM12 connector IEC 61076-2-101
Shock, vibration EN 50155
Status displayNo
Protective circuit/componentunwired
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Torque0.4 Nm (M12 connector)

Material

Flammability rating according to UL 94V0
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material of grip bodyPA 6.6
Material, knurlsZinc die-cast, nickel-plated
Standards/regulationsPA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Standards and Regulations

Standard designationM12 connector
Standards/regulationsIEC 61076-2-101
Standard designationShock, vibration
Standards/regulationsEN 50155
Flammability rating according to UL 94V0

Cable

Cable typeShielded black RADOX®
Cable type (abbreviation)28R
Conductor cross section3x 0.5 mm²
AWG signal line20
Conductor structure signal line19x 0.18 mm
Core diameter including insulation1.43 mm
Wire colorsWhite 1, white 2, white 3
Overall twist3 wires, twisted
ShieldingTinned copper braided shield
External sheath, colorblack
External cable diameter D5.3 mm ±0,3 mm
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Cable weight51 kg/km
Outer sheath, materialPE-X
Material conductor insulationPE-X
Conductor materialTin-plated Cu litz wires
Conductor resistance≤ 40.1 Ω/km
Nominal voltage, cable600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
Test voltage, cable3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistanceEN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation)-50 °C ... 120 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 1407296 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 3
Type of electrical connection, field-sided (EF005525) M12
Type of plug-in contact, field sided (EF006269) Male (plug)
Positioning cable feed, field-sided (EF005928) Straight
Type of electrical connection, box-sided (EF005524) Other
Positioning cable feed, box-sided (EF005927) Other
Cable length (EF000536) 2 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) Yes
Colour cable sheath (EF008249) Black
With LED indication (EF005950) No
Screened (EF000881) Yes
Cable type (EF000081) Multi-core
Vulcanize (EF004115) No
Material contact body (EF008248) CuSn
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -50 °C
Permitted cable outer temperature during assembling/handling (EF001685) -25 °C
Rated current In (EF008250) 4 A
Rated voltage (EF000228) 48 V
Degree of protection (IP) (EF005474) IP65

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.