PHOENIX CONTACT SACCBP-M12FSD-4CON-M16/0,5-937 SACCBP-M12FSD-4CON-M16/0,5-937 1423238 PHOENIX CONTACT Connector View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SACCBP-M12FSD-4CON-M16/0,5-937 1423238 PHOENIX CONTACT Connector

SACCBP-M12FSD-4CON-M16/0,5-937

1423238

PHOENIX CONTACT

50 Pcs.

Connector Conect. plug. to be apar. poster wall, 4-pole, Connecting female, straight, M12, encoding: D, Rear wall mount/bolt mount, M16 x 1.5, Bus line, Alternative product according to RoHS II without exception 6c (Pb &lt.; 0.1%) Item code: 1239401

Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1423238
Packing unit1
GTIN4055626340029
Custom tariff number85444290

Dimensions

Fixed cable length0.5
Back to top

Ambient conditions

Ambient temperature (operation)-25 ... -85
Back to top

General

Standards/regulationsaccording to IEC 61076-2-101
Overvoltage categoryII
Mounting typeRear wall/screw mounting
CodingD-coded
Thread typeM16 x 1.5
AWG signal line22
Rated surge voltage2.5 kV AC
Degree of pollution3
Degree of protectionIP67
Number of positions4
Current4 A
Voltage60 V
Back to top

Connection data

Connection methodBus line
Back to top

Standards and Regulations

Standards/specificationsaccording to IEC 61076-2-101
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.127440102
eCl@ss 8.027440103
eCl@ss 9.027440102
Back to top

ETIM

ETIM 5.0EC002061
ETIM 6.0EC002061
Back to top

ETIM for 1423238 Connectors (EC002635)
Feature Name Feature Value
Contact type (EF001587) Other
Number of data contacts (EF012232) 0
Number of power contacts (EF012216) 0
Number of control contacts (EF012217) 4
Type of housing (EF006980) Straight
Rated current In (EF008250) 4 A
Ambient temperature (EF002386) -25 °C
Rated voltage (EF000228) 48 V
Over voltage category (EF006785) II
Pollution degree (EF006786) 3
Type of locking (EF000208) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
With protective conductor (EF007468) No
Degree of protection (IP), mounted (EF007466) IP67
Screened (EF000881) No
With status indication (EF001602) No