PHOENIX CONTACT SACCBP-M12FSB-2CON-M16/2,0-915 SACCBP-M12FSB-2CON-M16/2,0-915 1401425 PHOENIX CONTACT Bus system flat-type plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SACCBP-M12FSB-2CON-M16/2,0-915 1401425 PHOENIX CONTACT Bus system flat-type plug

SACCBP-M12FSB-2CON-M16/2,0-915

1401425

PHOENIX CONTACT

50 Pcs.

Bus system flat-type plug Conect. plug. to be apar. poster wall, 5-pole, PUR, green RAL 6018, coding: B , Rear wall mount/screw mount, M16 x 1.5, Bus line, 0.25 mm², PROFIBUS, Alternative product according to RoHS II without exception 6c (Pb< 0.1%) item code: 1238666 Device connector rear mounting, 5-position, PUR, green RAL 6018, coding: B, Rear wall/screw mounting, M16 x 1.5, Bus line, 0.25 mm2, PROFIBUS, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1238666

Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Order information:Lock nut is included in the scope of delivery
Safety note
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Mounting
Mounting typeRear wall/screw mounting M16 x 1.5

Product properties
Product typeCircular connectors (device side)
Number of positions5
No. of cable outlets1
Shieldedyes
CodingB
Thread typeM12
Data management status
Article revision13
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialFKM
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated
Outer sheath, materialPUR
Conductor materialBare Cu litz wires

Electrical properties
Rated surge voltage1.5 kV AC
Contact resistance≤ 3 mΩ
Insulation resistance≥ 10 GΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)

Connection data
Conductor connection
Connection methodBus line
Contact connection typeSocket
Conductor cross section0.25 mm²

Mechanical properties
Mechanical data
Max. bending cycles3000000

Cable/line
Cable length2
PROFIBUS [915]
Cable weight74 kg/km
Number of positions2
Shieldedyes
Cable typePROFIBUS [915]
Conductor structure1x2xAWG24/19
Conductor structure signal line19x 0.14 mm
AWG signal line24
Conductor cross section2x 0.25 mm²
Wire diameter incl. insulation2.56 mm
External cable diameter8.00 mm ±0.4 mm
Outer sheath, materialPUR
External sheath, colorblue
Conductor materialBare Cu litz wires
Material wire insulationFoamed PE
Single wire, colorred, green
Thickness, outer sheathapprox. 0.80 mm
Overall twist2 wires, twisted
Optical shield covering70 %
Insulation resistance≥ 16 GΩ*km
Working capacitance28 nF (at 1 kHz)
Nominal voltage, cable≤ 100 V
Test voltage Core/Core3600 V DC
Minimum bending radius, flexible installation5 x D
Smallest bending radius, movable installation40 mm
Dynamic load capacity (bending)Max. bending cycles: 3000000, Bending radius: 60 mm, Acceleration: 4 m/s²
Tensile strength≤ 100 N
Flame resistanceaccording to IEC 60332-1
Resistance to oilResistant to mineral oils and grease
Ambient temperature (operation)-40 °C ... 80 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP67 (When plugged in)
IP65 (When plugged in)
IP65/IP67
Ambient temperature (operation)-25 ... -85 (Plug / socket)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)

Standards and regulations
Standards/specificationsaccording to IEC 61076-2-101

ETIM for 1401425 Connectors (EC002635)
Feature Name Feature Value
Contact type (EF001587) Other
Number of data contacts (EF012232) 0
Number of power contacts (EF012216) 0
Number of control contacts (EF012217) 5
Rated current In (EF008250) 4 A
Ambient temperature (EF002386) -25 °C
Rated voltage (EF000228) 48 V
Over voltage category (EF006785) III
Pollution degree (EF006786) 3
Material of contact surface (EF004020) Nickel
Housing material (EF001596) Plastic
Material thread ring (EF012304) Other
Type of locking (EF000208) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
With protective conductor (EF007468) No
Degree of protection (IP), mounted (EF007466) IP67
Screened (EF000881) Yes
With status indication (EF001602) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.