PHOENIX CONTACT SACCBP-M12FS-8CON-M16/2,0-940 SACCBP-M12FS-8CON-M16/2,0-940 1553381 PHOENIX CONTACT Bus system flat-type plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SACCBP-M12FS-8CON-M16/2,0-940 1553381 PHOENIX CONTACT Bus system flat-type plug

SACCBP-M12FS-8CON-M16/2,0-940

1553381

PHOENIX CONTACT

1 Pcs.

Bus system flat-type plug Conect. plug. to be apar. wall poster., 8-pole, PUR, water blue RAL5021, Female connection, straight, M12, encoding: A, to free cable end, Rear mounting, M16 x 1.5, Cable connection, cable length: 2 m, 0.14 mm², Ethernet, Alternative product according to RoHS II without exception 6c (Pb< 0.1%) item code: 1240032

Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1553381
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 183 (PC-2007)
GTIN4046356162364
Weight per Piece (excluding packing)114.800 g
Custom tariff number85444290
Country of originDE (Germany)

Dimensions

Length of cable2 m

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
Degree of protectionIP67

General

Rated current at 40°C2 A
Rated voltage30 V
Number of positions8
Insulation resistance≥ 100 MΩ
CodingA - standard
Status displayNo
Overvoltage categoryII
Degree of pollution3

Material

Flammability rating according to UL 94V0
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material, knurlsNickel-plated brass
Sealing materialNBR

Standards and Regulations

Flammability rating according to UL 94V0

Cable

Cable typeEthernet, flexible, CAT5
Cable type (abbreviation)94B
UL AWM style20963 (80°C/30 V)
Signal type/categoryEthernet CAT5 (IEC 11801), 1 Gbps
Cable structure4x2xAWG26/7; SF/UTP
Conductor cross section4x 2x 0.14 mm²
AWG signal line26
Conductor structure signal line7x 0.16 mm
Core diameter including insulation0.96 mm
Wire colorswhite/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Twisted pairs2 cores to the pair
Overall twist4 pairs for core
ShieldingAluminum-coated foil, tinned copper braided shield
Optical shield covering70 %
External sheath, colorwater blue RAL 5021
Outer sheath thickness1.05 mm
External cable diameter D6.4 mm ±0.2 mm
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Tensile strength GRP≤ 100 N
Cable weight47 kg/km
Outer sheath, materialPUR
Material conductor insulationFoamed PE
Conductor materialBare Cu litz wires
Insulation resistance≥ 500 MΩ*km
Loop resistance≤ 290.00 Ω/km
Cable capacity48 nF/km (at 1 kHz)
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)71.3 dB (with 1 MHz)
62.3 dB (at 4 МHz)
56.3 dB (at 10 MHz)
53.2 dB (at 16 MHz)
51.8 dB (at 20 МHz)
48.9 dB (at 31.25 МHz)
44.4 dB (at 62.5 МHz)
41.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Attenuation3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Return loss (RL)23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Signal runtime5.3 ns/m
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable≤ 100 V
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700 V (50 Hz, 1 min.)
Flame resistanceaccording to IEC 60332-1-2
Halogen-freeaccording to IEC 60754-1
Resistance to oilaccording to EN 60811-2-1
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C
Ambient temperature (storage/transport)-20 °C ... 80 °C

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”