PHOENIX CONTACT SACC-DSI-M12FSS-4CON-M16/4,5PE SACC-DSI-M12FSS-4CON-M16/4,5PE 1420019 PHOENIX CONTACT Flush-type connector, Power, 4-position, Socket, M12,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SACC-DSI-M12FSS-4CON-M16/4,5PE 1420019 PHOENIX CONTACT Flush-type connector, Power, 4-position, Socket, M12,..

SACC-DSI-M12FSS-4CON-M16/4,5PE

1420019

PHOENIX CONTACT

50 Pcs.

Flush-type connector, Power, 4-position, Socket, M12, S power, Rear mounting, M16 x 1.5, Individual wires, cable length: 4.5 m, 1.31 mm², UL/cUL stranded hook-up wire Conect. plug. to be apar. Wall poster., Power, 4-pole, Connection female, M12, S - Power, Rear mounting, M16 x 1.5, Single stranded wires, cable length: 4.5 m, 1.31 mm², UL/cUL switchgear twisted wire, Alternative product according to RoHS II without exception 6c (Pb< 0.1 %) 1239295 Device connector rear mounting, Power, 4-position, Socket, straight, M12, coding: S, on free cable end, Rear mounting, M16 x 1.5, Individual wires, cable length: 4.5 m, 1.31 mm2, UL/cUL stranded hook-up wire, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239295

Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Notes on operationThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Order information:Lock nut is included in the scope of delivery
GeneralContact connection method: Crimp connection
Safety note
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Mounting
Mounting typeRear mounting M16 x 1.5 With flat nut
Assembly noteWith flat nut

Product properties
Product typeCircular connectors (device side)
Sensor typePower
Number of positions4
No. of cable outlets1
Shieldedno
CodingS
Thread typeM12
Data management status
Article revision07
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialFKM
Contact materialCuZn
Contact surface materialAu
Contact carrier materialPA
Material for screw connectionZinc die-cast, nickel-plated
Conductor materialBare Cu litz wires

Electrical properties
Rated voltage in acc. with IEC 61076-2-101630 V
Rated surge voltage6 kV
6 kV AC
Contact resistance≤ 3 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN630 V
Nominal current IN12 A
Test voltage6 kV

Connection data
Conductor connection
Connection methodIndividual wires
Contact connection typeSocket
Conductor cross section1.31 mm²
Tightening torque3 Nm ... 4 Nm (M12 connector)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles> 100

Connector
Connection 1
Head designSocket
Head cable outletstraight
Head thread typeM12
CodingS
Connection 2
Head designfree cable end

Cable/line
Cable length4.5 m
Cable typeUL/cUL stranded hook-up wire
Signal type/categoryPower
Wire diameter incl. insulation2.2 mm
Single wire, colorblack 1, black 2, black 3, green/yellow
Cable cross section1.31 mm²
Conductor materialBare Cu litz wires
AWG signal line16
Material wire insulationmPPE
Halogen-freeyes
Flame resistancein acc. to UL 1581 VW1
Ambient temperature (operation)-40 °C ... 105 °C (cable, fixed installation)
-20 °C ... 105 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP67
IP65/IP67
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-20 °C ... 105 °C (Cable, flexible installation)
-40 °C ... 105 °C (cable, fixed installation)

Standards and regulations
Flame resistancein acc. to UL 1581 VW1
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-111
NoteIn line with