View larger
SAC-8P-MS/ 0,6-285/FS SH SCO
1403361
PHOENIX CONTACT
50 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Sensor/actuator cable, 8-position, PUR, highly flexible, gray RAL 7001, shielded, Plug straight M12 SPEEDCON, A-coded, on Socket straight M12 SPEEDCON, A-coded, cable length: 0.6 m, Twisted pair cable
| Orderkey | 1403361 |
|---|---|
| Packing unit | 1 |
| GTIN | 4046356649032 |
| Custom tariff number | 85444290 |
| Length of cable | 0.6 m |
|---|
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
|---|---|
| Degree of protection | IP65 |
| IP67 |
| Rated current at 40°C | 2 A |
|---|---|
| Rated voltage | 30 V AC |
| 30 V DC | |
| Number of positions | 8 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | A - standard |
| Status display | No |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
| Flammability rating according to UL 94 | HB |
|---|
| Cable type | PUR, gray, shielded |
|---|---|
| Cable type (abbreviation) | 285 |
| Cable abbreviation | Li12YC11Y-HF |
| Conductor cross section | 4x 2x 0.25 mm² (Signal line) |
| 1x 0.25 mm² (Drain wire) | |
| AWG signal line | 24 |
| Conductor structure signal line | 32x 0.10 mm |
| Wire colors | white-brown, green-yellow, gray-pink, blue-red |
| Twisted pairs | 2 cores to the pair |
| Overall twist | 4 pairs for core |
| Shielding | Tinned copper braided shield |
| Optical shield covering | 85 % |
| External sheath, color | gray RAL 7001 |
| External cable diameter D | 7.6 mm ±0.2 mm |
| Minimum bending radius, flexible installation | 7.5 x D |
| Number of bending cycles | 3000000 |
| Bending radius | 100 mm |
| Traversing path | 1.2 m |
| Traversing rate | 1.4 m/s |
| Acceleration | 2 m/s² |
| Outer sheath, material | PUR |
| Material conductor insulation | PES |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 100 MΩ*km |
| Nominal voltage, cable | 350 V |
| Test voltage, cable | 1200 V |
| Resistance to oil | very good oil and chemical resistance |
| Other resistance | ozone and UV resistant |
| Low adhesion | |
| abrasion-resistant | |
| notch tough | |
| Ambient temperature (operation) | -50 °C ... 80 °C (cable, fixed installation) |
| -40 °C ... 80 °C (cable, flexible installation) |
| REACh SVHC | |
|---|---|
| Lead 7439-92-1 | |
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| eCl@ss 4.0 | 27060306 |
|---|---|
| eCl@ss 4.1 | 27060306 |
| eCl@ss 5.0 | 27060300 |
| eCl@ss 5.1 | 27061800 |
| eCl@ss 6.0 | 27279200 |
| eCl@ss 7.0 | 27279218 |
| eCl@ss 8.0 | 27279218 |
| eCl@ss 9.0 | 27060311 |
| ETIM 4.0 | EC001855 |
|---|---|
| ETIM 5.0 | EC001855 |
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |
| UNSPSC 6.01 | 31251501 |
|---|---|
| UNSPSC 7.0901 | 31251501 |
| UNSPSC 11 | 31251501 |
| UNSPSC 12.01 | 31251501 |