| Cable length | 10 m |
| PUR halogen-free black [PUR] |
| Dimensional drawing |  |
| Shielded | yes |
| UL AWM Style | 20549 |
| Cable weight | 45 kg/km |
| Cable type | PUR halogen-free black |
| Short symbol | Li9YV1-C-V1-11Y |
| Cable type (abbreviation) | PUR |
| External cable diameter | 5.9 mm ±0.2 mm |
| Outer sheath, material | PUR |
| External sheath, color | black-gray RAL 7021 |
| Conductor material | Bare Cu litz wires |
| Conductor structure signal line | 18x 0.10 mm |
| AWG signal line | 26 |
| Conductor cross section | 8x 0.14 mm² (Signal line) |
| Material, filler | PE |
| Material wire insulation | PP |
| Thickness, insulation | ≥ 0.21 mm (Signal line) |
| Wire diameter incl. insulation | 1 mm ±0.02 mm (Signal line) |
| Single wire, color | white, brown, green, yellow, gray, pink, blue, red |
| Overall twist | 8 wires around filler to the core |
| Length of twist, overall twist | 58 mm |
| Shielding | Tinned copper braided shield |
| Optical shield covering | 85 % |
| Nominal voltage, cable | ≤ 300 V AC |
| Test voltage Core/Shield | ≥ 2000 V AC (for 60 s) |
| Test voltage, cable | ≥ 3000 V AC (Spark test) |
| Cable resistance | 139 Ω/km (at 20 °C) |
| Cable insulation resistance | 1 GΩ*km (at 20 °C) |
| Smallest bending radius, fixed installation | 29.5 mm |
| Smallest bending radius, movable installation | 59 mm |
| Number of bending cycles | 2000000 |
| Bending radius | 59 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Flame resistance | according to UL 758/1581 (horizontal) |
| in accordance with UL 758/1581 FT2 |
| Other resistance | hydrolysis and microbe resistant |
| Resistant to salt water |
| Low adhesion |
| abrasion-resistant |
| partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
| Ambient temperature (operation) | -25 °C ... 80 °C (Cable, flexible installation) |
| -40 °C ... 80 °C (cable, fixed installation) |