PHOENIX CONTACT SAC-8P-M12FS/ 5,0-PUR/M12FS SH SAC-8P-M12FS/ 5,0-PUR/M12FS SH 1445224 PHOENIX CONTACT Cable for sensors/actuators, 8-pole, PUR halogen-free.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-8P-M12FS/ 5,0-PUR/M12FS SH 1445224 PHOENIX CONTACT Cable for sensors/actuators, 8-pole, PUR halogen-free..

SAC-8P-M12FS/ 5,0-PUR/M12FS SH

1445224

PHOENIX CONTACT

15 Pcs.

Cable for sensors/actuators, 8-pole, PUR halogen-free, black-gray RAL 7021, shielded, Female straight connection M12, coded A, A connection socket straight M12, coded, cable length: 5 m Sensor/actuator cable, 8-pole, halogen-free PUR, greyish black RAL 7021, shielded, Straight connection female M12, coding: A, a Straight connection female M12, coding: A, cable length: 5 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Cable, sensor/actuator, 8-pin, PUR halogen free, black-gray RAL 7021, shielded, Plug straight M12, coding A, to Socket, straight M12, coding A, cable length: 5 m

Business

The code of the applicationOne million four hundred forty five thousand two hundred twenty four
The amount of the package (C#)1 Unit
The minimum quantity of the order15 Pcs
NoteThe production is linked to the application (no removal)
GTINFour trillion forty six billion three hundred fifty six million five hundred eighty two thousand four hundred seven
Weight per piece (excluding packing)292,700 GRM
The number of corporate and commercialEighty five million four hundred forty four thousand two hundred ninety
The country-of-originPL (Poland).

Measures

The length of the cableA 5-m

Environmental conditions

The degree of protectionIP65
IP67

The general

Rated current at 40 °CTwo
Rated voltage30 V AC
30 V DC
The number of poles in theEight
The resistance of the insulation≥ 100 MΩ
CodingThe standard
An indication of the state ofDon't
Over voltage categoryII
The degree of impurity,Three

The Material

Class of flammability according to UL 94Hemoglobin (HB)
The Material of the contactCuZn
Material on the surface of the contactNi/Au
The Material supporting the contactTPU GF
The Material of the body of the cableTPU, hardly inflammable, self-extinguishing
The Material of the anti -Zinc die casting is under pressure, nickel-plated
The Material of the sealingO

The rules and the provisions of

Class of flammability according to UL 94Hemoglobin (HB)

The line

The type of cablePUR halogen-free black
Cable type (code)PURE
The code for the cableLiF9YC11Y
The style of the UL AWM20549 / 10493 (80 °C / 300 V)
The value of the driver8x 0.25 mm2 (signal Line)
The line of the signal WIRETwenty four
The mounting of the conductive signal line on the32x 0.10 mm
The diameter of the conductor, including the insulation1,17 mm ±0.02 mm
The density of the wall insulationca. 0.2 mm
The color of the driverbrown, blue, green, yellow, white, pink, blue, and red
Stranded in totalThe 8 conductors in the core of soul
The shieldwire, copper-plated or coated with zinc
Coverage of the visual of the shield85 %
Outer shell, colorthe black-gray RAL 7021
The thickness of the wall of outer Jacketca. 0.5 mm
The outer diameter of the cable DAt 5.9 mm ±0.2 mm
Minimum bend radius of, the position of the fixed5 x D
Minimum bend radius of, the position of the flexible10 x D
Number of cycles of the bendingTwo million
Minimum bend radius of insertion for the belt to drag-and-drop10 x D
The course of the shiftA 10-m
The speed of the scroll3 m/sec.
The acceleration10 m/s2)
The weight of the cable53 kg/km
An external covering material,PURE
An insulating Material of the conductorPP
The Material of the conductorCopper cable
The resistance of the insulationA ≥ 1 GΩ*km (at 20 °C)
The resistance of the conductor≤ 78 Ω/km (at 20 °C)
The nominal voltage of the line≤ 300 V AC
The voltage of the test of the≥ 3000 V AC (Test for spark)
Test voltage conductor/screenAt ≥ 2000 V AC (for 60 s),
Special featureshimself to the door-handles
The Anti-flammabilityaccording to to UL FT-2 in
UL 758/1581 (horizontal)
UL 758/1581 FT2
in accordance with DIN EN 60332-2-2 (20 sec.)
The absence of a halogen-freeacc. to DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
The other resistorsresistant to hydrolysis and microbes.
resistant to sea water
with a low-tack
with a low-tack
with good UV resistance in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)Operating temperature: -40 °C ... 80 °C (Cable, available to set)
-25 °C ... 80 °C (Cable, available to a mobile)

Environmental And Product Compliance

REACh-SVHC
Lead 7439-92-1
As China RoHSThe period for the approved purpose (EFUP) is 50 years old
For more information on hazardous materials, see manufacturer's declaration in the Download

Ratings

eCl@ss

the eCl@ss 4.0Twenty seven million sixty thousand three hundred six
the eCl@ss 4.1Twenty seven million sixty thousand three hundred six
the eCl@ss 5.0Twenty seven million sixty one thousand eight hundred one
eCl@ss 5.1Twenty seven million sixty one thousand eight hundred
eCl@ss 6.0Twenty seven million two hundred seventy nine thousand two hundred
eCl@ss 7.0Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 8.0Twenty seven million two hundred seventy nine thousand two hundred eighteen
the eCl@ss 9.0Twenty seven million sixty thousand three hundred eleven

ETIM

ETIM 3.0EC001855
ETIM 4.0EC001855
ETIM 5.0EC001855
ETIM 6.0EC001855
ETIM 7.0EC001855

UNSPSC

UNSPSC 6.01Thirty one million two hundred fifty one thousand five hundred one
UNSPSC 7.0901Thirty one million two hundred fifty one thousand five hundred one
UNSPSC 11Thirty one million two hundred fifty one thousand five hundred one
UNSPSC 12.01Thirty one million two hundred fifty one thousand five hundred one
UNSPSC 13.2Thirty one million two hundred fifty one thousand five hundred one

ETIM for 1445224 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 8
Type of electrical connection, field-sided (EF005525) M12
Type of plug-in contact, field sided (EF006269) Female (bus)
Positioning cable feed, field-sided (EF005928) Straight
Type of electrical connection, box-sided (EF005524) M12
Type of plug-in contact, box-sided (EF008386) Female (bus)
Positioning cable feed, box-sided (EF005927) Straight
Cable length (EF000536) 5 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) Yes
Colour cable sheath (EF008249) Other
With LED indication (EF005950) No
Screened (EF000881) Yes
Cable type (EF000081) Multi-core
Vulcanize (EF004115) No
Material contact body (EF008248) CuZn
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -40 °C
Permitted cable outer temperature during assembling/handling (EF001685) -25 °C
Rated current In (EF008250) 2 A
Rated voltage (EF000228) 30 V
Degree of protection (IP) (EF005474) IP65

Product Datasheet