View larger
SAC-8P-M12FS/ 5,0-PUR/M12FS SH
1445224
PHOENIX CONTACT
15 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Cable, sensor/actuator, 8-pin, PUR halogen free, black-gray RAL 7021, shielded, Plug straight M12, coding A, to Socket, straight M12, coding A, cable length: 5 m
| The code of the application | One million four hundred forty five thousand two hundred twenty four |
|---|---|
| The amount of the package (C#) | 1 Unit |
| The minimum quantity of the order | 15 Pcs |
| Note | The production is linked to the application (no removal) |
| GTIN | Four trillion forty six billion three hundred fifty six million five hundred eighty two thousand four hundred seven |
| Weight per piece (excluding packing) | 292,700 GRM |
| The number of corporate and commercial | Eighty five million four hundred forty four thousand two hundred ninety |
| The country-of-origin | PL (Poland). |
| The length of the cable | A 5-m |
|---|
| The degree of protection | IP65 |
|---|---|
| IP67 |
| Rated current at 40 °C | Two |
|---|---|
| Rated voltage | 30 V AC |
| 30 V DC | |
| The number of poles in the | Eight |
| The resistance of the insulation | ≥ 100 MΩ |
| Coding | The standard |
| An indication of the state of | Don't |
| Over voltage category | II |
| The degree of impurity, | Three |
| Class of flammability according to UL 94 | Hemoglobin (HB) |
|---|---|
| The Material of the contact | CuZn |
| Material on the surface of the contact | Ni/Au |
| The Material supporting the contact | TPU GF |
| The Material of the body of the cable | TPU, hardly inflammable, self-extinguishing |
| The Material of the anti - | Zinc die casting is under pressure, nickel-plated |
| The Material of the sealing | O |
| Class of flammability according to UL 94 | Hemoglobin (HB) |
|---|
| The type of cable | PUR halogen-free black |
|---|---|
| Cable type (code) | PURE |
| The code for the cable | LiF9YC11Y |
| The style of the UL AWM | 20549 / 10493 (80 °C / 300 V) |
| The value of the driver | 8x 0.25 mm2 (signal Line) |
| The line of the signal WIRE | Twenty four |
| The mounting of the conductive signal line on the | 32x 0.10 mm |
| The diameter of the conductor, including the insulation | 1,17 mm ±0.02 mm |
| The density of the wall insulation | ca. 0.2 mm |
| The color of the driver | brown, blue, green, yellow, white, pink, blue, and red |
| Stranded in total | The 8 conductors in the core of soul |
| The shield | wire, copper-plated or coated with zinc |
| Coverage of the visual of the shield | 85 % |
| Outer shell, color | the black-gray RAL 7021 |
| The thickness of the wall of outer Jacket | ca. 0.5 mm |
| The outer diameter of the cable D | At 5.9 mm ±0.2 mm |
| Minimum bend radius of, the position of the fixed | 5 x D |
| Minimum bend radius of, the position of the flexible | 10 x D |
| Number of cycles of the bending | Two million |
| Minimum bend radius of insertion for the belt to drag-and-drop | 10 x D |
| The course of the shift | A 10-m |
| The speed of the scroll | 3 m/sec. |
| The acceleration | 10 m/s2) |
| The weight of the cable | 53 kg/km |
| An external covering material, | PURE |
| An insulating Material of the conductor | PP |
| The Material of the conductor | Copper cable |
| The resistance of the insulation | A ≥ 1 GΩ*km (at 20 °C) |
| The resistance of the conductor | ≤ 78 Ω/km (at 20 °C) |
| The nominal voltage of the line | ≤ 300 V AC |
| The voltage of the test of the | ≥ 3000 V AC (Test for spark) |
| Test voltage conductor/screen | At ≥ 2000 V AC (for 60 s), |
| Special features | himself to the door-handles |
| The Anti-flammability | according to to UL FT-2 in |
| UL 758/1581 (horizontal) | |
| UL 758/1581 FT2 | |
| in accordance with DIN EN 60332-2-2 (20 sec.) | |
| The absence of a halogen-free | acc. to DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| The other resistors | resistant to hydrolysis and microbes. |
| resistant to sea water | |
| with a low-tack | |
| with a low-tack | |
| with good UV resistance in accordance with DIN EN ISO 4892-2-A | |
| Ambient temperature (operation) | Operating temperature: -40 °C ... 80 °C (Cable, available to set) |
| -25 °C ... 80 °C (Cable, available to a mobile) |
| REACh-SVHC | |
|---|---|
| Lead 7439-92-1 | |
| As China RoHS | The period for the approved purpose (EFUP) is 50 years old |
| For more information on hazardous materials, see manufacturer's declaration in the Download |
| the eCl@ss 4.0 | Twenty seven million sixty thousand three hundred six |
|---|---|
| the eCl@ss 4.1 | Twenty seven million sixty thousand three hundred six |
| the eCl@ss 5.0 | Twenty seven million sixty one thousand eight hundred one |
| eCl@ss 5.1 | Twenty seven million sixty one thousand eight hundred |
| eCl@ss 6.0 | Twenty seven million two hundred seventy nine thousand two hundred |
| eCl@ss 7.0 | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 8.0 | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| the eCl@ss 9.0 | Twenty seven million sixty thousand three hundred eleven |
| ETIM 3.0 | EC001855 |
|---|---|
| ETIM 4.0 | EC001855 |
| ETIM 5.0 | EC001855 |
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |
| UNSPSC 6.01 | Thirty one million two hundred fifty one thousand five hundred one |
|---|---|
| UNSPSC 7.0901 | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 11 | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 12.01 | Thirty one million two hundred fifty one thousand five hundred one |
| UNSPSC 13.2 | Thirty one million two hundred fifty one thousand five hundred one |
| Feature Name | Feature Value |
|---|---|
| Number of poles (EF001391) | 8 |
| Type of electrical connection, field-sided (EF005525) | M12 |
| Type of plug-in contact, field sided (EF006269) | Female (bus) |
| Positioning cable feed, field-sided (EF005928) | Straight |
| Type of electrical connection, box-sided (EF005524) | M12 |
| Type of plug-in contact, box-sided (EF008386) | Female (bus) |
| Positioning cable feed, box-sided (EF005927) | Straight |
| Cable length (EF000536) | 5 m |
| Material of cable sheath (EF004136) | Other |
| Halogen free (EF000025) | Yes |
| Colour cable sheath (EF008249) | Other |
| With LED indication (EF005950) | No |
| Screened (EF000881) | Yes |
| Cable type (EF000081) | Multi-core |
| Vulcanize (EF004115) | No |
| Material contact body (EF008248) | CuZn |
| Material of contact surface (EF004020) | Other |
| Permitted cable outer temperature after assembling without vibration (EF001686) | -40 °C |
| Permitted cable outer temperature during assembling/handling (EF001685) | -25 °C |
| Rated current In (EF008250) | 2 A |
| Rated voltage (EF000228) | 30 V |
| Degree of protection (IP) (EF005474) | IP65 |