PHOENIX CONTACT SAC-8P-100,0-PUR/M12FS SH VA SAC-8P-100,0-PUR/M12FS SH VA 1404965 PHOENIX CONTACT Sensor/actuator cable, 8-pos., PUR, halogen free, RAL 7.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-8P-100,0-PUR/M12FS SH VA 1404965 PHOENIX CONTACT Sensor/actuator cable, 8-pos., PUR, halogen free, RAL 7..

SAC-8P-100,0-PUR/M12FS SH VA

1404965

PHOENIX CONTACT

5 Pcs.

Sensor/actuator cable, 8-pos., PUR, halogen free, RAL 7021 (black gray), shielded, free cable end, to straight M12 socket, A-coded, cable length: 100 m, high-grade steel knurl Sensor/actuator cable, 8 poles, halogen-free PUR, greyish black RAL 7021, shielded, free cable end, M12 straight connection socket, A-coded, cable length: 100 m, stainless steel knurling

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1404965
Packing unit1 pc
Minimum order quantity5 pc
GTIN4046356730051
Weight per Piece (excluding packing)0.000 g
Custom tariff number85444290
Country of originPL (Poland)

Drawings



Dimensional drawing

Dimensional drawing
M12 x 1 socket, straight, shielded

Circuit diagram

Circuit diagram
Contact assignment of the M12 socket



Schematic diagram

Schematic diagram
Pin assignment M12 socket, 8-pos., A-coded, view female side

Cable cross section

Cable cross section
PUR halogen-free black [PUR]



Back to top

Dimensions

Length of cable100 m
Stripping length of the free conductor end50 mm
Back to top

Ambient conditions

Degree of protectionIP65
IP67
IP68
IP69K
Back to top

General

Rated current at 40°C2 A
Rated voltage30 V AC
30 V DC
Number of positions8
Insulation resistance≥ 100 MΩ
CodingA - standard
Status displayNo
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Back to top

Material

Flammability rating according to UL 94HB
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsStainless steel
Sealing materialNBR
Back to top

Standards and Regulations

Flammability rating according to UL 94HB
Back to top

Cable

Cable typePUR halogen-free black
Cable type (abbreviation)PUR
Cable abbreviationLiF9YC11Y
UL AWM style20549 / 10493 (80°C/300 V)
Conductor cross section8x 0.25 mm² (Signal line)
AWG signal line24
Conductor structure signal line32x 0.10 mm
Core diameter including insulation1.17 mm ±0.02 mm
Thickness, insulationapprox. 0.2 mm
Wire colorsBrown, white, green, yellow, gray, pink, blue, red
Overall twist8 wires around filler to the core
ShieldingTinned copper braided shield
Optical shield covering85 %
External sheath, colorblack-gray RAL 7021
Outer sheath thicknessapprox. 0.5 mm
External cable diameter D5.9 mm ±0.2 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles2000000
Minimum bending radius, drag chain applications10 x D
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Cable weight53 kg/km
Outer sheath, materialPUR
Material conductor insulationPP
Conductor materialBare Cu litz wires
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Conductor resistance≤ 78 Ω/km (at 20 °C)
Nominal voltage, cable≤ 300 V AC
Test voltage, cable≥ 3000 V AC (Spark test)
Test voltage Core/Shield≥ 2000 V AC (for 60 s)
Special propertiesFlexible cable conduit capable
Flame resistancein acc. with UL FT-2
according to UL 758/1581 (horizontal)
in accordance with UL 758/1581 FT2
According to DIN EN 60332-2-2 (20 s)
Halogen-freein accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Other resistancehydrolysis and microbe resistant
Resistant to salt water
Low adhesion
Low adhesion
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.027060300
eCl@ss 4.127060300
eCl@ss 5.027061800
eCl@ss 5.127061800
eCl@ss 6.027279200
eCl@ss 7.027279218
eCl@ss 8.027279218
eCl@ss 9.027060311
Back to top

ETIM

ETIM 3.0EC001855
ETIM 4.0EC001855
ETIM 5.0EC001855
ETIM 6.0EC001855
ETIM 7.0EC001855
Back to top

UNSPSC

UNSPSC 6.0131251501
UNSPSC 7.090131251501
UNSPSC 1131251501
UNSPSC 12.0131251501
UNSPSC 13.231251501
UNSPSC 19.031251501
UNSPSC 20.031251501
UNSPSC 21.031251501
Back to top

ETIM for 1404965 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 8
Type of electrical connection, field-sided (EF005525) Other
Positioning cable feed, field-sided (EF005928) Other
Type of electrical connection, box-sided (EF005524) M12
Type of plug-in contact, box-sided (EF008386) Female (bus)
Positioning cable feed, box-sided (EF005927) Straight
Cable length (EF000536) 100 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) Yes
Colour cable sheath (EF008249) Other
With LED indication (EF005950) No
Screened (EF000881) Yes
Cable type (EF000081) Multi-core
Vulcanize (EF004115) No
Material contact body (EF008248) CuZn
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -40 °C
Permitted cable outer temperature during assembling/handling (EF001685) -25 °C
Rated current In (EF008250) 2 A
Rated voltage (EF000228) 30 V
Degree of protection (IP) (EF005474) IP65

Product Datasheet