SAC-5P-M12MS/0,22-115 0,055

1407251

PHOENIX CONTACT

50 Pcs.

Sensor/actuator cable - SAC-5P-M12MS/0,22-115 0,055 - 1407251 Sensor/actuator cable, 5-pole, halogen-free PUR, greyish black RAL 7021, Straight male connector M12, coding: A, to free cable end, cable length: 0.22 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Sensor/actuator cable, 5-position, PUR halogen-free, black-gray RAL 7021, Plug straight M12, A-coded, on free cable end, cable length: 0.22 m

Key Commercial Data

Orderkey1407251
Packing unit1
GTIN4046356771184
Custom tariff number85444290

Dimensions

Length of cable0.22 m
Stripping length of the free conductor end55 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
Degree of protectionIP65
IP67
IP68

General

Rated current at 40°C4 A
Rated voltage48 V AC
60 V DC
Number of positions5
Insulation resistance≥ 100 MΩ
CodingA - standard
Standards/regulationsM12 connector IEC 61076-2-101
Status displayNo
Overvoltage categoryII
Degree of pollution3
Torque0.4 Nm (M12 connector)

Material

Flammability rating according to UL 94HB
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated

Standards and Regulations

Standard designationM12 connector
Standards/regulationsIEC 61076-2-101
Flammability rating according to UL 94HB

Cable

Cable typePUR, black, 5th conductor gray
Cable type (abbreviation)115
Cable abbreviationLi9Y11Y-HF
UL AWM style20549 / 10493 (80°C/300 V)
Conductor cross section5x 0.34 mm²
AWG signal line22
Conductor structure signal line42x 0.10 mm
Core diameter including insulation1.27 mm ±0.02 mm
Thickness, insulation≥ 0.21 mm
Wire colorsBrown, white, blue, black, gray
Overall twist5 cores, twisted
External sheath, colorblack-gray RAL 7021
Outer sheath thicknessapprox. 0.7 mm
External cable diameter D5 mm ±0.15 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles4000000
Bending radius50 mm
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Cable weight35 kg/km
Outer sheath, materialPUR
Material, fillerPP
Material conductor insulationPP
Conductor materialBare Cu litz wires
Conductor resistance≤ 58 Ω/km
Nominal voltage, cable≤ 300 V
Test voltage, cable≥ 3000 V
Special propertiesFlexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
flexible
Flame resistancein accordance with DIN UL-Style 20549
in accordance with UL 758/1581 FT2
Halogen-freein accordance with DIN VDE 0472 part 815
Resistance to oilin accordance with DIN EN 60811-2-1
Other resistancepartly UV-resistant in accordance with DIN EN ISO 4892-2-A
hydrolysis and microbe resistant
Resistant to salt water
Low adhesion
abrasion-resistant
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

eCl@ss

eCl@ss 4.027060306
eCl@ss 4.127060306
eCl@ss 5.027061801
eCl@ss 5.127061800
eCl@ss 6.027279200
eCl@ss 7.027279218
eCl@ss 8.027279218
eCl@ss 9.027060311

ETIM

ETIM 3.0EC001855
ETIM 4.0EC001855
ETIM 5.0EC001855
ETIM 6.0EC001855
ETIM 7.0EC001855

UNSPSC

UNSPSC 6.0131251501
UNSPSC 7.090131251501
UNSPSC 1131251501
UNSPSC 12.0131251501
UNSPSC 13.231251501

ETIM for 1407251 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 5
Type of electrical connection, field-sided (EF005525) M12
Type of plug-in contact, field sided (EF006269) Male (plug)
Positioning cable feed, field-sided (EF005928) Straight
Type of electrical connection, box-sided (EF005524) Other
Positioning cable feed, box-sided (EF005927) Other
Cable length (EF000536) 0.22 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) Yes
Colour cable sheath (EF008249) Other
With LED indication (EF005950) No
Screened (EF000881) No
Cable type (EF000081) Multi-core
Vulcanize (EF004115) No
Material contact body (EF008248) CuSn
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -40 °C
Permitted cable outer temperature during assembling/handling (EF001685) -25 °C
Rated current In (EF008250) 4 A
Rated voltage (EF000228) 48 V
Degree of protection (IP) (EF005474) IP65