PHOENIX CONTACT SAC-5P-5,0-921 /M12FS SAC-5P-5,0-921 /M12FS 1424428 PHOENIX CONTACT Cable bus system SAC-5P-5,0-921 /M12FS 1424428 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5P-5,0-921 /M12FS 1424428 PHOENIX CONTACT Cable bus system SAC-5P-5,0-921 /M12FS 1424428

SAC-5P-5,0-921 /M12FS

1424428

PHOENIX CONTACT

50 Pcs.

Cable bus system - SAC-5P-5,0-921 /M12FS - 1424428 Bus system cable, CANopen®, 5-pole, cable length: 5 m Bus system cable, CANopen®, 5-position, PUR halogen-free, black RAL 9005, cable length: 5 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeData cable preassembled
Sensor typeCANopen®
Number of positions5
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Interfaces
Signal type/categoryCANopen®

Electrical properties
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Cable/line
Cable length5 m
CANopen®/DeviceNet™, PUR, black [921]
Dimensional drawingtnjkbpxvav.jpg
Cable weight90 kg/km
UL AWM Style21198 (80°C/300 V)
Number of positions4
Shieldedyes
Cable typeCANopen®/DeviceNet™, PUR, black [921]
Conductor structure2xAWG24/19+2xAWG22/19
Conductor structure signal line19x 0.13 mm
AWG signal line24
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter6.70 mm ±0.3 mm
Outer sheath, materialPUR
External sheath, colorblack RAL 9005
Conductor materialTin-plated Cu litz wires
Material wire insulationFoamed PE (Data cable)
PE (Power supply)
Single wire, colorred-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
Optical shield covering80 %
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance120 Ω ±10 % (with 1 MHz)
Cable capacitynom. 40 nF/km (Data cable)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation67 mm
Dynamic load capacity (bending)Max. bending cycles: 5000000, Bending radius: 70 mm, Bending radius: 10 x D, Traversing path: 4.5 m, Traversing rate: 3 m/s, Acceleration: 3 m/s², Ambient temperature: ≤ 70 °C
Shield attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistanceUL 1581, Sec. 1060 (FT-1)
IEC 60332-1
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)
≤ 70 °C (cable, drag chain applications)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP68

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.