Sensor/Actuator Cable, 5-Pole, Free Cable End, to Straight Female M12, Coding: A, Cable Length: 25 m, Outdoor Application, Stainless Steel Knurling Cable for sensors/actuators Sensor/actuator cable, 5-position, free cable end, on Socket straight M12, coding: A, cable length: 25 m, for outdoor applications, with high-grade steel knurl

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeSensor/actuator cable
Number of positions5
ApplicationExternal areas
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialFPM
Material of grip bodyPP
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPP
Material for screw connectionStainless steel

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Protective circuitunwired

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
Typefree cable end
Connection 2
TypeSocket straight M12
Number of positions5
Coding typeA

Cable/line
Cable length25 m
PE-X black [28X]
Dimensional drawinghyaeumhlob.jpg
Shieldedyes
Cable weight85 kg/km
Cable typePE-X black
Short symbolLi2X2X-C-V1-2X
Cable type (abbreviation)28X
External cable diameter7.25 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack-gray RAL 7021
Thickness, outer sheathapprox. 0.7 mm
Material, inner sheathPE-X
Inner sheath thicknessapprox. 0.5 mm
Conductor materialBare Cu litz wires
Conductor structure signal line28x 0.15 mm
AWG signal line20
Conductor cross section5x 0.5 mm²
Material, fillerPP yarn
Material wire insulationPE-X
Thickness, insulationapprox. 0.3 mm (Core insulation)
Wire diameter incl. insulation1.6 mm ±0.5 mm
Single wire, colorbrown, white, blue, black, gray
Overall twist5 wires around filler to the core
Length of twist, overall twist68 mm
ShieldingBraided copper wires
Optical shield covering85 %
Nominal voltage, cable≤ 300 V AC
Test voltage Core/Shield≥ 1000 V AC (for 10 s)
Test voltage, cable≥ 3000 V AC (Spark test)
Cable resistance≤ 39 Ω/m (at 20 °C)
Cable insulation resistance≥ 100 MΩ*km (at 20 °C)
Working capacitance≤ 110 pF (Line-line)
≤ 200 pF (Line-shield)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles1000000
Minimum bending radius, drag chain applications10 x D
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Resistance to oilAccording to DIN EN 60811-2-1, 168 h at 100°C
According to DIN EN 50306
Flame resistanceAccording to DIN EN 60332-1-2
according to DIN EN 50266-2-5
Other resistanceResistance to fuels according to IEC 60811, 168 h at 70°C
UV resistant according to DIN VDE 0276-605
UV resistant in accordance with DIN EN ISO 4892-2-A (750 h)
Special propertiesInductance approx. 0.48 mH/km
Irradiated
Ambient temperature (operation)-15 °C ... 105 °C (Cable, flexible installation)
-15 °C ... 105 °C (Cable, flexible installation)
-40 °C ... 105 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP68
IP69K
Ambient temperature (operation)-40 °C ... 105 °C (Plug / socket)
-40 °C ... 85 °C (On sudden changes in temperature (according to IEC 60512-11-4))

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

ETIM for 1533789 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 5
Type of electrical connection, field-sided (EF005525) Other
Positioning cable feed, field-sided (EF005928) Other
Type of electrical connection, box-sided (EF005524) M12
Type of plug-in contact, box-sided (EF008386) Female (bus)
Positioning cable feed, box-sided (EF005927) Straight
Cable length (EF000536) 25 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) No
Colour cable sheath (EF008249) Other
With LED indication (EF005950) No
Screened (EF000881) Yes
Cable type (EF000081) Multi-core
Vulcanize (EF004115) No
Material contact body (EF008248) CuSn
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -40 °C
Permitted cable outer temperature during assembling/handling (EF001685) -15 °C
Rated current In (EF008250) 4 A
Rated voltage (EF000228) 48 V
Degree of protection (IP) (EF005474) IP65

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.