View larger
SAC-5P-20,0-PVC/M12FS SH VA
1495826
PHOENIX CONTACT
25 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Type | Sensor/Actuator Cable |
| No. of poles | 5 |
| Application | Standard |
| Number of cable outlets | 1 |
| Coding | at |
| Insulation characteristics | |
| Overvoltage Category | II |
| Degree of pollution | 3 |
| Combustibility class according to UL 94 | HB |
| Gasket material | NBR |
| Grip material | TPU, flame-retardant, self-extinguishing |
| Contact Material | CuSn |
| Contact Surface Material | Ni/Au |
| Contact Insert Material | TPU GF |
| Screw connection material | Stainless steel |
| Mass Resistivity | ≤ 5 mΩ |
| Insulation Resistance | ≥ 100 MΩ |
| Rated voltage UN | 48 V AC |
| 60 V DC | |
| Rated Current IN | 4 A |
| Protection Circuit | without circuit |
| Mechanical data | |
| Manoeuvring cycles | ≥ 100 |
| Status Reporting | no |
| Available Status Indication | no |
| Connection 1 | |
| type | Free conductor end |
| Connection 2 | |
| type | M12 straight socket |
| No. of poles | 5 |
| Encoding Type | at |
| Cable Length | 20 m |
| Black PVC [PVC] | |
| Dimensioned Drawing | |
| Line Weight | 55 kg/km |
| No. of poles | 5 |
| Shielded | Yes |
| Cable Type | Black PVC [PVC] |
| Line Signal Conductor Structure | 42x 0.10 mm |
| AWG Signal Line | 22 |
| Conductor cross-section | 5x 0.34 mm² (Signal Line) |
| Wire diameter with insulating sheath | 1.35 mm ±0.02 mm |
| Conductor Outer Diameter | 5.9 mm ±0.2 mm |
| Outer Sheath, Material | PVC |
| Outer sheath, color | black RAL 9005 |
| Conductor material | Bare Cu Wire |
| Material filler | PVC |
| Material, Wire Insulation | PVC |
| Single conductor, color | brown, white, blue, black, grey |
| Insulation wall thickness | ≥ 0.23 mm (Wire Insulation) |
| ≥ 0.76 mm (Outer Sheath) | |
| Full stranding | 5 conductors around fillers to the core |
| Optical Shielded Cover | 85 % |
| Conductor resistance max. | ≤ 58 Ω/km (at 20 °C) |
| Insulation Resistance | ≥ 10 MΩ*km (at 20 °C) |
| Nominal cable voltage | ≤ 300 V |
| Test voltage | ≥ 3000 V |
| Minimum bending radius, fixed | 5 x D |
| Minimum bending radius, flexible | 10 x D |
| Minimum bending radius, fixed | 30 mm |
| Minimum bending radius, movable | 59 mm |
| Flame Resistance | according to UL-Style 2464 |
| Oil Resistance | according to DIN EN 60811-2-1 |
| Ambient temperature (operating) | -25 °C ... 80 °C (cables, fixed laying) |
| -5 °C ... 80 °C (Cables, mobile installation) | |
| Environmental conditions | |
| Degree of protection | IP65 |
| IP67 | |
| Ambient temperature (operating) | -25 °C ... 90 °C (Female Connector / Connector) |
| -25 °C ... 80 °C (cables, fixed laying) | |
| -5 °C ... 80 °C (Cables, mobile installation) | |
| Standard Definition | M12 connector |
| Standards/Regulations | IEC 61076-2-101 |