View larger
SAC-5P-100,0-28R RAIL 0,5
1559186
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Type | Data cable by the meter |
| Number of poles | 5 |
| application | Railway applications |
| Shielded | Yes |
| Cable length | 100 m |
| RADOX®black, shielded [28R] | |
| Dimension Scheme | ![]() |
| Shielded | Yes |
| Cable Weight | 70 kg/km |
| Cable type | RADOX®black, shielded |
| Cable Type (abbreviation) | 28R |
| Cable Outer Diameter | 6.2 mm ±0.3 mm |
| Outer Wrap, Material | PE-X |
| Outer Wrap, Color | black |
| Conductive Material | Tinned Cu Conductor |
| Conductor Construction Signal Cable | 19x 0.18 mm |
| AWG Signal Line | 20 |
| Line Section | 5x 0.5 mm² |
| Material: Conductor Insulation | PE-X |
| Conductor diameter incl. insulation | 1.43 mm |
| Single Driver, Color | White 1, White 2, White 3, White 4, White 5 |
| Total cabling | 5 longitudinally stranded conductors |
| Screening | Tinned Copper Wire Mesh |
| Nominal Voltage Cable | 600 V AC (Conductive-Ground, U)0) |
| 1000 V AC (Conduct-to-Earth, U) | |
| ≤ 720 V AC (conductive-ground) | |
| ≤ 1200 V AC (Ground-Conductor, U)m) | |
| ≤ 900 V DC (Conductive-Ground, V0) | |
| ≤ 1500 V DC (conductor-conductor) | |
| Test Voltage Cable | 3500 V AC (50 Hz, 5 min.) |
| 8400 V DC (50 Hz, 5 min.) | |
| Line Resistance | ≤ 40.1 Ω/km |
| Minimum bending radius, fixed | 3 x D |
| Minimum bending radius, flexibly positioned | 4 x D |
| Fire protection in vehicles on rails | BS 6853 (Category Ia, Ib, II) |
| GM/RT 2130 (Category Ia, Ib, II) | |
| EN 45545 (Hazard Level HL1 - HL3) | |
| DIN 5510 (Fire Protection Level 1, 2, 3, 4) | |
| NF F16-101 (Category A1, A2, B) | |
| NF F16-101 (Class C / F0) | |
| NFPA 130 | |
| UNI IEC 11170 (Hazard Level LR1 - LR4) | |
| Absence of halogens | according to EN 50267-2-1 |
| Oil Resistance | according to IRM 902, 72 h at 100 °C |
| Flue gas density | BS 6853 D.8.7 |
| EN 61034-2 | |
| UL 1685, 12 (FT4) | |
| Fire Gas Toxicity | BS 6853 B.1 |
| EN 50305, 9.2 | |
| Corrosion of fire gases | EN 50267-2-2 |
| Flame Resistance | EN 60332-1-2 |
| EN 50266 | |
| EN 60332-3-25 | |
| NF C32-070, 2.1 | |
| NF C32-070, 2.2 | |
| UL 1685, 12 (FT4) | |
| according to ISO 6722-1 5.22 (UN ECE-R 118.01) | |
| Other resistances | Fuel resistant according to IRM 903, 168 h at 70 °C |
| Ambient Temperature (Service) | -25 °C ... 90 °C (Cable, movable arrangement) |
| -50 °C ... 120°C (cable, fixed arrangement) | |
| Feature Name | Feature Value |
|---|---|
| Conductor surface (EF010804) | Other |
| Diameter conductor (EF001621) | 1.43 mm |
| Nominal cross section conductor (EF000060) | 0.5 mm² |
| Conductor category (EF001632) | Class 6 = very flexible |
| Number of cores (EF001792) | 5 |
| Core identification (EF000067) | Other |
| Screen over stranding element (EF001623) | Braiding |
| Longitudinal water blocking cable (EF011011) | No |
| Radial water blocking cable (EF011012) | No |
| Suitable for underground installation (EF003689) | No |
| Protective sheath (EF001691) | None |
| Material outer sheath (EF001625) | Other |
| Specification material outer sheath (EF011806) | Other |
| Colour outer sheath (EF001618) | Black |
| Low smoke according to EN IEC 61034-2 (EF003799) | No |
| Oil resistant according to EN IEC 60811-404 (EF009770) | No |
| Outer diameter approx. (EF003921) | 6.2 mm |
| Min. permitted bending radius, moving application/free movement (EF011802) | 25 mm |
| Min. permitted bending radius, stationary application/permanent installation (EF011803) | 19 mm |
| Permitted cable outer temperature during assembling/handling (EF001685) | -25 °C |
| Permitted cable outer temperature after assembling without vibration (EF001686) | -50 °C |
| Category (EF001619) | Other |