| Cable type | PE-X black |
|---|
| Cable type (abbreviation) | 28X |
|---|
| Cable abbreviation | Li2X2X |
|---|
| Conductor cross section | 5x 0.5 mm² |
|---|
| AWG signal line | 20 |
|---|
| Conductor structure signal line | 28x 0.15 mm |
|---|
| Core diameter including insulation | 1.6 mm ±0.5 mm |
|---|
| Thickness, insulation | approx. 0.3 mm (Core insulation) |
|---|
| Wire colors | Brown, white, blue, black, gray |
|---|
| Overall twist | 5 wires around filler to the core |
|---|
| Length of twist, overall twist | 68 mm |
|---|
| External sheath, color | black-gray RAL 7021 |
|---|
| Outer sheath thickness | approx. 1.25 mm |
|---|
| External cable diameter D | 6.8 mm ±0.2 mm |
|---|
| Minimum bending radius, fixed installation | 5 x D |
|---|
| Minimum bending radius, flexible installation | 10 x D |
|---|
| Number of bending cycles | 2000000 |
|---|
| Minimum bending radius, drag chain applications | 10 x D |
|---|
| Traversing path | 10 m |
|---|
| Traversing rate | 3 m/s |
|---|
| Acceleration | 10 m/s² |
|---|
| Cable weight | 70 kg/km |
|---|
| Outer sheath, material | PE-X |
|---|
| Material, filler | PP yarn |
|---|
| Material conductor insulation | PE-X |
|---|
| Conductor material | Bare Cu litz wires |
|---|
| Insulation resistance | ≥ 100 MΩ*km (at 20 °C) |
|---|
| Conductor resistance | ≤ 39 Ω/m (at 20 °C) |
|---|
| Nominal voltage, cable | ≤ 300 V AC |
|---|
| Test voltage, cable | ≥ 3000 V AC (Spark test) |
|---|
| Special properties | Irradiated |
|---|
| Flame resistance | According to DIN EN 60332-1-2 |
|---|
| according to DIN EN 50266-2-5 |
|---|
| according to IEC 60332-3-25 (bunched fire test) |
|---|
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
|---|
| in accordance with DIN EN 50267-2-1 |
|---|
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
|---|
| According to DIN EN 50306 |
|---|
| Other resistance | Resistance to fuels according to IEC 60811, 168 h at 70°C |
|---|
| UV resistant according to DIN VDE 0276-605 |
|---|
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
|---|
| -15 °C ... 105 °C (cable, flexible installation) |
|---|
| 20 °C ±5 °C (cable, drag chain applications) |
|---|