PHOENIX CONTACT SAC-4PM12MSD/1,7-936/BP-M12FSD SAC-4PM12MSD/1,7-936/BP-M12FSD 1564079 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4PM12MSD/1,7-936/BP-M12FSD 1564079 PHOENIX CONTACT Bus system cable

SAC-4PM12MSD/1,7-936/BP-M12FSD

1564079

PHOENIX CONTACT

1 Pcs.

Bus system cable

Automation > Sensor-actuator patch cord
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1564079
Packing unit1 pc
Minimum order quantity5 pc
NoteMade to Order (non-returnable)
GTIN4046356321655
Weight per Piece (excluding packing)183.900 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable1.7 m

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
Degree of protectionIP65
IP67

General

Rated current at 40°C4 A
Rated voltage250 V
Number of positions4
CodingD - data
Signal type/categoryPROFINET
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100

Material

Flammability rating according to UL 94V0
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR

Standards and Regulations

Flammability rating according to UL 94V0

Cable

Cable typeEthernet
Cable type (abbreviation)936
Cable structure1x4xAWG22/7; SF/TQ
Conductor cross section4x 0.34 mm²
AWG signal line22
Conductor structure signal line7x 0.25 mm
Core diameter including insulation1.95 mm
Wire colorswhite-blue, orange-yellow
Overall twistStar quad
ShieldingPlastic-coated aluminum foil, tinned copper braided shield
Optical shield covering100 %
External sheath, colorblack RAL 9005
Outer sheath thickness≥ 0.8 mm
External cable diameter D7.25 mm ±0,3 mm
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Cable weight81 g/m
Outer sheath, materialPE-X
Material conductor insulationPE-X
Conductor materialsilver-plated Cu litz wires
Conductor resistance≤ 54.4 Ω/km
Working capacitance≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Attenuation2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
Return Loss35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Signal speed66 c
Shield attenuation40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable300 V AC
Test voltage, cable2000 V AC (50 Hz, 5 minutes)
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Classifications


Product Datasheet