PHOENIX CONTACT SAC-4P-MS/1,0-28R/MS SCO RAIL SAC-4P-MS/1,0-28R/MS SCO RAIL 1095178 PHOENIX CONTACT Sensor/actuator cable, 4-position, PE-X halogen-free, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-MS/1,0-28R/MS SCO RAIL 1095178 PHOENIX CONTACT Sensor/actuator cable, 4-position, PE-X halogen-free, ..

SAC-4P-MS/1,0-28R/MS SCO RAIL

1095178

PHOENIX CONTACT

50 Pcs.

Sensor/actuator cable, 4-position, PE-X halogen-free, black, shielded, Plug straight M12, A-coded, on Plug straight M12, A-coded, cable length: 1 m, For railway applications Sensor/actuator cable, 4-pole, halogen-free PE-X, black RAL 9005, shielded, M12 straight male connector, coding: A, a M12 straight male connector, coding: A, cable length: 1 m, For railway applications

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1095178
Packing unit1
GTIN4055626923130
Custom tariff number85444290

Drawings



Dimensional drawing

Dimensional drawing
M12 SPEEDCON plug, straight, shielded

Schematic diagram

Schematic diagram
Pin assignment M12 plug, 4-pos., A-coded, view plug side



Cable cross section

Cable cross section
Shielded black RADOX®[28R]

Back to top

Dimensions

Length of cable1 m
Back to top

General

Rated current at 40°C4 A
Rated voltage250 V AC
250 V DC
Number of positions4
Insulation resistance≥ 100 MΩ
CodingA - standard
Standards/regulationsM12 connector IEC 61076-2-101
Shock, vibration EN 50155
Status displayNo
Protective circuit/componentunwired
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Back to top

Material

Flammability rating according to UL 94V0
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material of grip bodyPA 6.6
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR
Standards/regulationsPA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Back to top

Standards and Regulations

Standards/specificationsM12 connector IEC 61076-2-101
Shock, vibration EN 50155
Flammability rating according to UL 94V0
Back to top

Cable

Cable typeShielded black RADOX®
Cable type (abbreviation)28R
Conductor cross section4x 0.5 mm²
AWG signal line20
Conductor structure signal line19x 0.18 mm
Core diameter including insulation1.43 mm
Wire colorsWhite 1, white 2, white 3, white 4
Overall twist4 wires, twisted
ShieldingTinned copper braided shield
External sheath, colorblack
External cable diameter D5.4 mm ±0,3 mm
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Cable weight56 kg/km
Outer sheath, materialPE-X
Material conductor insulationPE-X
Conductor materialTin-plated Cu litz wires
Conductor resistance≤ 40.1 Ω/km
Nominal voltage, cable600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
Test voltage, cable3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistanceEN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation)-50 °C ... 120 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)
Back to top

Classifications

eCl@ss

eCl@ss 9.027060311
Back to top

ETIM

ETIM 6.0EC001855
ETIM 7.0EC001855
Back to top

ETIM for 1095178 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 4
Type of electrical connection, field-sided (EF005525) M12
Type of plug-in contact, field sided (EF006269) Male (plug)
Positioning cable feed, field-sided (EF005928) Straight
Type of electrical connection, box-sided (EF005524) M12
Type of plug-in contact, box-sided (EF008386) Male (plug)
Positioning cable feed, box-sided (EF005927) Straight
Cable length (EF000536) 1 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) Yes
Colour cable sheath (EF008249) Other
With LED indication (EF005950) No
Screened (EF000881) Yes
Cable type (EF000081) Multi-core
Vulcanize (EF004115) No
Material contact body (EF008248) CuSn
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -50 °C
Permitted cable outer temperature during assembling/handling (EF001685) -25 °C
Rated current In (EF008250) 4 A
Rated voltage (EF000228) 48 V
Degree of protection (IP) (EF005474) IP65