| Cable type | Ethernet |
|---|
| Cable type (abbreviation) | 936 |
|---|
| Cable structure | 1x4xAWG22/7; SF/TQ |
|---|
| Conductor cross section | 4x 0.34 mm² |
|---|
| AWG signal line | 22 |
|---|
| Conductor structure signal line | 7x 0.25 mm |
|---|
| Core diameter including insulation | 1.95 mm |
|---|
| Wire colors | white-blue, orange-yellow |
|---|
| Overall twist | Star quad |
|---|
| Shielding | Plastic-coated aluminum foil, tinned copper braided shield |
|---|
| Optical shield covering | 100 % |
|---|
| External sheath, color | black RAL 9005 |
|---|
| Outer sheath thickness | ≥ 0.8 mm |
|---|
| External cable diameter D | 7.25 mm ±0,3 mm |
|---|
| Minimum bending radius, fixed installation | 6 x D |
|---|
| Minimum bending radius, flexible installation | 10 x D |
|---|
| Cable weight | 81 g/m |
|---|
| Outer sheath, material | PE-X |
|---|
| Material conductor insulation | PE-X |
|---|
| Conductor material | silver-plated Cu litz wires |
|---|
| Conductor resistance | ≤ 54.4 Ω/km |
|---|
| Working capacitance | ≤ 65 pF (core-core) |
|---|
| ≤ 100 pF (core-shield) |
|---|
| Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
|---|
| Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
|---|
| 76 dB (at 4 МHz) |
|---|
| 67 dB (at 10 MHz) |
|---|
| 60 dB (at 31.5 МHz) |
|---|
| 56 dB (at 62.5 МHz) |
|---|
| 53 dB (at 100 MHz) |
|---|
| Attenuation | 2 dB (with 1 MHz) |
|---|
| 4 dB (at 4 МHz) |
|---|
| 6.5 dB (at 10 MHz) |
|---|
| 10.5 dB (at 31.5 МHz) |
|---|
| 14 dB (at 62.5 МHz) |
|---|
| 18 dB (at 100 MHz) |
|---|
| Return Loss | 35 dB (at 4 МHz) |
|---|
| 35 dB (at 10 MHz) |
|---|
| 35 dB (at 31.5 МHz) |
|---|
| 33 dB (at 62.5 МHz) |
|---|
| 33 dB (at 100 MHz) |
|---|
| Signal speed | 66 c |
|---|
| Shield attenuation | 40 dB (30 MHz ≤ f ≤ 100 MHz) |
|---|
| Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
|---|
| Nominal voltage, cable | 300 V AC |
|---|
| Test voltage, cable | 2000 V AC (50 Hz, 5 minutes) |
|---|
| Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
|---|
| GM/RT 2130 (Category Ia, Ib, II) |
|---|
| EN 45545 (Risk level HL1 - HL3) |
|---|
| DIN 5510 (Fire protection level 1, 2, 3, 4) |
|---|
| NF F16-101 (Category A1, A2, B) |
|---|
| NF F16-101 (Class C/F0) |
|---|
| NFPA 130 |
|---|
| UNI CEI 11170 (Risk level LR1 - LR4) |
|---|
| Flame resistance | EN 60332-1-2 |
|---|
| EN 50266 |
|---|
| EN 60332-3-25 |
|---|
| NF C32-070, 2.1 |
|---|
| NF C32-070, 2.2 |
|---|
| UL 1685, 12 (FT4) |
|---|
| in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
|---|
| Halogen-free | According to EN 50267-2-1 |
|---|
| Resistance to oil | according to IRM 902, 72 h at 100 °C |
|---|
| Other resistance | Resistance to fuels according to IRM 903, 168 h at 70 °C |
|---|
| Concentration of fumes | BS 6853 D.8.7 |
|---|
| EN 61034-2 |
|---|
| UL 1685, 12 (FT4) |
|---|
| Fume corrosiveness | EN 50267-2-2 |
|---|
| Fume toxicity | BS 6853 B.1 |
|---|
| EN 50305, 9.2 |
|---|
| Ambient temperature (operation) | -50 °C ... 90 °C (cable, fixed installation) |
|---|
| -40 °C ... 90 °C (cable, flexible installation) |
|---|