PHOENIX CONTACT SAC-4P-M12Y/2X3,0-140/M12FS VP SAC-4P-M12Y/2X3,0-140/M12FS VP 1502604 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-M12Y/2X3,0-140/M12FS VP 1502604 PHOENIX CONTACT Sensor/actuator cable

SAC-4P-M12Y/2X3,0-140/M12FS VP

1502604

PHOENIX CONTACT

10 Pcs.

Sensor/actuator cable Sensor/Actuator Cable, 3-Pole, M12 Straight Connector, A-Coding, M12 Straight Female to M12, A-Coding, 3 m Cable Length Sensor/actuator cable, 3-position, PUR/PVC, yellow, Plug straight M12, coding: A, on Socket straight M12, coding: A, cable length: 3 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeDistributor with cable
Number of positions3
No. of cable outlets2
Shieldedno
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Insulation resistance≥ 10 GΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayno
Status display presentNo

Connector
Connection 1
TypePlug straight M12
Number of positions3
Coding typeA
Connection 2
TypeSocket straight M12
Number of positions3
Coding typeA

Cable/line
Cable length3 m
PUR/PVC yellow [140]
Dimensional drawingwujdupmqjr.jpg
Cable weight39 kg/km
UL AWM Style20549
Number of positions4
Shieldedno
Cable typePUR/PVC yellow [140]
Conductor structure signal line42x 0.10 mm
AWG signal line22
Conductor cross section4x 0.34 mm² (Signal line)
Wire diameter incl. insulation1.5 mm ±0.05 mm
External cable diameter5.20 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, coloryellow
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorbrown, white, blue, black
Thickness, insulationapprox. 0.30 mm (Core insulation)
≥ 0.38 mm (Outer cable sheath)
approx. 0.35 mm (Inner sheath)
Overall twist4 wires, twisted
Max. conductor resistancemax. 58 Ω/km (at 20 °C)
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Smallest bending radius, fixed installation52 mm
Smallest bending radius, movable installation52 mm
Dynamic load capacity (bending)Max. bending cycles: 2000000, Bending radius: 52 mm, Traversing path: 5 m, Traversing rate: 3 m/s
Flame resistancein accordance with DIN UL-Style 20549
Ambient temperature (operation)-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP68
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Product Datasheet