PHOENIX CONTACT SAC-4P-M12MSD/ 4,0-936/M12MSD SAC-4P-M12MSD/ 4,0-936/M12MSD 1401034 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-M12MSD/ 4,0-936/M12MSD 1401034 PHOENIX CONTACT Bus system cable

SAC-4P-M12MSD/ 4,0-936/M12MSD

1401034

PHOENIX CONTACT

50 Pcs.

Bus system cable Bus system cable, PROFINET, 4-pole, halogen-free PE-X, black RAL 9005, shielded, M12 straight male connector, coding: D-coded, a M12 straight male connector, coding: D-coded, cable length: 4 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1401034
Packing unit1
GTIN4046356517461
Custom tariff number85444290

Mechanical characteristics

Number of positions4
Shieldedyes
Insertion/withdrawal cycles≥ 100
Cable diameter7.25 mm
Length of cable4 m
Degree of protectionIP65/IP67/IP69K
No. of cable outlets1

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-40 °C ... 90 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)
Degree of protectionIP65
IP67
IP68

Material data

Flammability rating according to UL 94V0
Contact carrier materialPA 6.6
Contact materialCuSn
Contact surface materialNi/Au
Cable gland materialZinc die-cast, nickel-plated
Sealing materialNBR
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005

Standards and Regulations

Flammability rating according to UL 94V0

Line characteristics

Cable typeEthernet
Cable structure1x4xAWG22/7; SF/TQ
Conductor cross section4x 0.34 mm²
AWG signal line22
Conductor structure signal line7x 0.25 mm
Core diameter including insulation1.95 mm
External cable diameter7.25 mm ±0,3 mm
Wire colorswhite-blue, orange-yellow
External sheath, colorblack RAL 9005
Transmission mediumCopper
Conductor resistance≤ 54.4 Ω/km
Working capacitance≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Wave attenuation2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
Return Loss35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Signal speed66 c
Shield attenuation40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable300 V AC
Test voltage, cable2000 V AC (50 Hz, 5 minutes)
Overall twistStar quad
ShieldingPlastic-coated aluminum foil, tinned copper braided shield
Optical shield covering100 %
Outer sheath, materialPE-X
Material conductor insulationPE-X
Conductor materialsilver-plated Cu litz wires
Cable weight81 g/m
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.