Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 250 V AC |
| 250 V DC | |
| Number of positions | 4 |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Torque | 0.4 Nm |
| Cable type | PE-X black |
|---|---|
| Cable type (abbreviation) | 28X |
| Cable abbreviation | Li2X2X |
| Conductor cross section | 4x 0.5 mm² (Signal line) |
| AWG signal line | 20 |
| Conductor structure signal line | 28x 0.15 mm |
| Core diameter including insulation | 1.6 mm ±0.05 mm (Signal line) |
| Thickness, insulation | approx. 0.3 mm (Core insulation) |
| approx. 0.6 mm (Outer cable sheath) | |
| Wire colors | brown, white, blue, black |
| Overall twist | 4 wires, twisted |
| Length of twist, overall twist | 61.6 mm |
| External sheath, color | black-gray RAL 7021 |
| External cable diameter D | 5.2 mm ±0.2 mm |
| Smallest bending radius, fixed installation | 26 mm |
| Smallest bending radius, movable installation | 52 mm |
| Number of bending cycles | 2000000 |
| Bending radius | 52 mm |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 44 kg/km |
| Outer sheath, material | PE-X |
| Material conductor insulation | PE-X |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 100 MΩ*km (at 20 °C) |
| Conductor resistance | ≤ 39 Ω/km (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V AC |
| Test voltage, cable | ≥ 3000 V AC |
| Special properties | Irradiated |
| Flame resistance | according to DIN 60332-1-2 |
| according to DIN EN 50266-2-5 | |
| according to IEC 60332-3-25 (bunched fire test) | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Other resistance | UV resistant according to DIN VDE 0276-605 |
| Concentration of fumes | according to DIN EN 61034 |
| Fume corrosiveness | according to IEC 60754 |
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
| -15 °C ... 105 °C (cable, flexible installation) |
| eCl@ss 4.0 | 27060306 |
|---|---|
| eCl@ss 4.1 | 27060306 |
| eCl@ss 5.0 | 27061801 |
| eCl@ss 5.1 | 27061801 |
| eCl@ss 6.0 | 27061801 |
| eCl@ss 7.0 | 27060308 |
| eCl@ss 8.0 | 27279218 |
| eCl@ss 9.0 | 27060308 |
| ETIM 2.0 | EC000830 |
|---|---|
| ETIM 3.0 | EC001855 |
| ETIM 4.0 | EC001855 |
| ETIM 5.0 | EC001855 |
| ETIM 6.0 | EC001262 |
| ETIM 7.0 | EC001262 |
| UNSPSC 6.01 | 31251501 |
|---|---|
| UNSPSC 7.0901 | 31251501 |
| UNSPSC 11 | 31251501 |
| UNSPSC 12.01 | 31251501 |
| UNSPSC 13.2 | 31251501 |
| UNSPSC 18.0 | 26121604 |
| UNSPSC 19.0 | 26121604 |
| UNSPSC 20.0 | 26121604 |
| UNSPSC 21.0 | 26121604 |