Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Ring cable lug, number of connections: 8, number of positions: 4, width: 55.6 mm, height: 80.9 mm, color: gray, mounting type: Insertion in base strip Test pin strip, rated voltage: 400 V, rated current: 24 A, number of connections: 8, number of poles: 4, connection type: Ring wire terminal, 1st floor, Sizing cross-section: 6 mm², mounting class: Wall mounting, color: gray

Automation > Accessories/spare parts for terminals
Enclosures connectivity

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1029994
Packing unit1
Catalog pagePage 644 (C-1-2019)
GTIN4055626532622
Custom tariff number85366990

Drawings



Circuit diagram

Circuit diagram

Circuit diagram

Circuit diagram



Back to top

General

Number of positions4
Number of levels1
Number of connections8
Potentials4
Nominal cross section6 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Rated surge voltage4 kV
Test surge voltage5 kV
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition1.31 W
Maximum load current30 A (with 10 mm² conductor cross section)
Current Ith24 A
Nominal voltage UN400 V AC/DC
Open side panelNo
Shock protection test specificationDIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protectionguaranteed
Note regarding shock protection
Result of surge voltage testTest passed
Surge voltage test setpoint4.8 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint1.89 kV
Result of tight fit on supportTest passed
Setpoint5 N
Result of thermal testTest passed
Proof of thermal characteristics (needle flame) effective duration30 s
Oscillation, broadband noise test resultTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2008-03
Test spectrumService life test category 2, bogie-mounted
Test frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s2)2/Hz
Acceleration3.12 g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
Shock test resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2008-03
Shock formHalf-sine
Acceleration30g
Shock duration18 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Back to top

Dimensions

Width55.6 mm
Length81.9 mm
Height80.9 mm
Plate thickness1 mm ... 4 mm
Pitch8.2 mm
Back to top

Connection data

Connection1 level
Connection methodRing cable lug
Screw threadNo 8 UNC
Stripping length12 mm
Tightening torque, min1.5 Nm
Tightening torque max1.8 Nm
Connection in acc. with standardIEC 60947-7-1
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible8
2 conductors with same cross section, solid min.0.5 mm²
2 conductors with same cross section, solid max.6 mm²
2 conductors with same cross section, stranded min.0.5 mm²
2 conductors with same cross section, stranded max.6 mm²
Cable lug connection according to standardDIN 46234:1980-03
Min. cross section for cable lug connection0.5 mm²
Max. cross section for cable lug connection10 mm²
Hole diameter, min.4.3 mm
Cable lug width, max.8 mm
Bolt diameter4.1 mm
Cable lug connection according to standardDIN 46237:1970-07
Min. cross section for cable lug connection0.5 mm²
Max. cross section for cable lug connection10 mm²
Hole diameter, min.4.3 mm
Cable lug width, max.8 mm
Bolt diameter4.1 mm
Internal cylindrical gageA5
Back to top

Mounting

Mounting typeInsertion in base strip
Plate thickness1 mm ... 4 mm
Back to top

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1
Flammability rating according to UL 94V0
Back to top

Classifications

eCl@ss

eCl@ss 4.027141118
eCl@ss 4.127141118
eCl@ss 5.027141118
eCl@ss 5.127141100
eCl@ss 6.027141100
eCl@ss 7.027141126
eCl@ss 8.027141126
eCl@ss 9.027141126
Back to top

ETIM

ETIM 4.0EC000897
ETIM 5.0EC000902
ETIM 6.0EC000902
ETIM 7.0EC000902
Back to top

UNSPSC

UNSPSC 6.0130211811
UNSPSC 7.090139121410
UNSPSC 1139121410
UNSPSC 12.0139121410
UNSPSC 13.239121410
UNSPSC 18.039121410
UNSPSC 19.039121410
UNSPSC 20.039121410
UNSPSC 21.039121410
Back to top

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.