View larger
RIF-2-RPT-LV-230AC/4X21/EX
2909739
PHOENIX CONTACT
10 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2909739 |
|---|---|
| Packing unit | 10 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626379692 |
| Weight per Piece (excluding packing) | 108.300 g |
| Custom tariff number | 85364900 |
| Country of origin | CN (China) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Ambient temperature (operation) | -40 °C ... 50 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Nominal input voltage UN | 230 V AC |
|---|---|
| Input voltage range in reference to UN | see diagram |
| Mains frequency | 50/60 Hz |
| Typical input current at UN | 6.5 mA |
| Typical response time | 5 ms ... 15 ms |
| Typical release time range | 5 ms ... 20 ms |
| Coil voltage | 230 V AC |
| Protective circuit | Varistor |
| Operating voltage display | Yellow LED |
| Power dissipation for nominal condition | 1.5 W |
| Contact type | 4 PDTs |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (At 24 mA) |
| Min. switching current | 5 mA (at 24 V) |
| Maximum inrush current | 16 A (20 ms, N/O contact) |
| Limiting continuous current | 5 A (see diagram) |
| Interrupting rating (ohmic load) max. | 120 W (at 24 V DC) |
| 124 W (at 48 V DC) | |
| 108 W (at 60 V DC) | |
| 52 W (at 110 V DC) | |
| 48 W (at 220 V DC) | |
| 1250 VA (for 250 V AC) | |
| Switching capacity | 2 A (at 24 V, DC13) |
| 0.22 A (at 120 V, DC13) | |
| 0.11 A (at 250 V, DC13) | |
| 1.5 A (at 24 V, AC15) | |
| 1.5 A (at 120 V, AC15) | |
| 1 A (at 240 V, AC15) |
| Test voltage relay winding/relay contact | 2.5 kVrms(50 Hz, 1 min.) |
|---|---|
| Test voltage relay contact/relay contact | 2 kVrms(50 Hz, 1 min.) |
| Operating mode | 100% operating factor |
| Degree of protection | IP20 (Relay base) |
| RT III (Relay) | |
| Mechanical service life | approx. 2x 107cycles |
| ATEX | II 3G Ex ec nC IIC T4 Gc |
| EU-type examination certificate | IBExU17ATEXB014X |
| IECEx | Ex ec nC IIC T4 Gc |
| IECEx certificate | IECEx IBE 17.0032X |
| UL, USA/Canada | Class I, Div. 2, Groups A, B, C, D T4 |
| Class I, Zone 2, Group IIC | |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Connection name | Coil side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) | |
| 0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) | |
| Conductor cross section AWG | 26 ... 16 (solid) |
| 26 ... 16 (flexible) |
| Connection name | Contact side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) | |
| 0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) | |
| Conductor cross section AWG | 26 ... 16 (solid) |
| 26 ... 16 (flexible) |
| Standards/regulations | DIN EN 50178 |
|---|---|
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 2.5 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Designation | Ex zone |
| Standards/regulations | EN/IEC 60079-0 |
| EN/IEC 60079-7 | |
| EN/IEC 60079-15 | |
| Flammability rating according to UL 94 | V2 |
| ATEX | II 3G Ex ec nC IIC T4 Gc |
| IECEx | Ex ec nC IIC T4 Gc |
| UL, USA/Canada | Class I, Div. 2, Groups A, B, C, D T4 |
| Class I, Zone 2, Group IIC |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Other |
| Complete with socket (EF003359) | Yes |
| With detachable clamps (EF003340) | No |
| With LED indication (EF005950) | Yes |
| Rated control supply voltage AC 50 Hz (EF003978) | 184 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 184 V |
| Voltage type for actuating (EF008242) | AC |
| Drive, polarization (EF003355) | Polarized |
| Drive, switching attitude (EF003356) | Mono stable |
| Number of contacts as normally closed contact (EF008255) | 0 |
| Number of contacts as normally open contact (EF008256) | 0 |
| Number of contacts as change-over contact (EF008257) | 4 |
| Type of switch contact (EF003358) | Single contact |
| With forced-guided contacts (EF003357) | No |
| Material of contact insert (EF008521) | Other |
| Material of contact surface (EF004020) | Untreated |
| Nominal current (EF000001) | 0.0065 A |
| Degree of protection (IP) (EF005474) | IP20 |
| Width (EF000008) | 31 mm |
| Height (EF000040) | 96 mm |
| Depth (EF000049) | 75 mm |