PHOENIX CONTACT RIF-1-RSC-LDP-24DC/1X21 RIF-1-RSC-LDP-24DC/1X21 2903358 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

RIF-1-RSC-LDP-24DC/1X21 2903358 PHOENIX CONTACT Relay Module

RIF-1-RSC-LDP-24DC/1X21

2903358

PHOENIX CONTACT

10 Pcs.

Relay Module Pre-assembled relay module with screw connection, consisting of: relay socket, relay with power contact, plug-in indication/antiparasitic module and clamping flange. Contact type: 1 switched contact. Input voltage: 24 V DC

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2903358
Packing unit10 pc
Catalog pagePage 342 (C-5-2017)
GTIN4046356732918
Weight per Piece (excluding packing)70.000 g
Custom tariff number85364190
Country of originCN (China)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)

Dimensions

Width16 mm
Height89 mm
Depth75 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V DC
Input voltage range in reference to UNsee diagram
Typical input current at UN18 mA
Typical response time8 ms
Typical release time10 ms
Coil voltage24 V DC
Protective circuitDamping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.43 W

Contact side

Contact type1 PDT
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage12 V (at 10 mA)
Min. switching current10 mA (at 12 V)
Maximum inrush current50 A (20 ms, N/O contact)
Limiting continuous current11 A (see diagram)
Interrupting rating (ohmic load) max.264 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
2750 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
6 A (at 24 V, AC15)
6 A (at 120 V, AC15)
6 A (at 250 V, AC15)

Connection data 1

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Conductor cross section solid0.5 mm² ... 4 mm²
Conductor cross-section solid (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
Conductor cross section flexible0.5 mm² ... 4 mm²
0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG20 ... 10 (solid)
20 ... 12 (flexible)
Torque0.5 Nm ... 0.6 Nm

Connection data 2

Connection nameContact side
Connection methodScrew connection
Stripping length8 mm
Conductor cross section solid0.5 mm² ... 4 mm²
Conductor cross-section solid (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
Conductor cross section flexible0.5 mm² ... 4 mm²
0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG20 ... 10 (solid)
20 ... 12 (flexible)
Torque0.5 Nm ... 0.6 Nm

General

Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)
Test voltage relay winding/relay contact4 kVrms(50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20 (Relay base)
RT III (Relay)
Mechanical service lifeapprox. 3x 107cycles
Service life, electricalsee diagram
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)70 g

Standards and Regulations

Standards/regulationsDIN EN 50178
Rated insulation voltage250 V AC
Rated surge voltage6 kV
Insulationsafe isolation
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Articles in set

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.