PHOENIX CONTACT RIF-1-RPT-LV-24AC/2X21MS RIF-1-RPT-LV-24AC/2X21MS 1049232 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

RIF-1-RPT-LV-24AC/2X21MS 1049232 PHOENIX CONTACT Relay Module

RIF-1-RPT-LV-24AC/2X21MS

1049232

PHOENIX CONTACT

10 Pcs.

Relay Module Pre-assembled relay module with push-in connection, consisting of: relay socket, relay with power contact, plug-in indication/antiparasitic module and clamping flange. Contact type: 2 investor contacts. Input voltage: 24 V AC

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1049232
Packing unit10 pc
Minimum order quantity10 pc
NoteMade to Order (non-returnable)
GTIN4055626661018
Weight per Piece (excluding packing)70.850 g
Custom tariff number85364110
Country of originCN (China)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width16 mm
Height93 mm
Depth75 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V AC
Input voltage range in reference to UNsee diagram
Mains frequency50/60 Hz
Typical input current at UN32 mA
Typical response time3 ms ... 12 ms
Typical release time range3 ms ... 20 ms
Coil voltage24 V AC
Protective circuitVaristor
Operating voltage displayYellow LED
Power dissipation for nominal condition0.8 W

Contact side

Contact type2 PDT
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (at 10 mA)
Min. switching current10 mA (At 5 V)
Maximum inrush current12 A (20 ms, N/O contact)
Limiting continuous current8 A (see diagram)
Interrupting rating (ohmic load) max.192 W (at 24 V DC)
124 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
57 W (at 220 V DC)
2000 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 250 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 250 V, AC15)

Connection data input side

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

Connection data output side

Connection nameContact side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

General

Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)
Test voltage relay winding/relay contact4 kVrms(50 Hz, 1 min.)
Test voltage PDT/PDT2.5 kVrms(50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20 (Relay base)
RT III (Relay)
Mechanical service lifeapprox. 107cycles
Mounting positionany
Assembly instructionsIn rows with zero spacing

Standards and Regulations

Standards/regulationsDIN EN 50178
Rated surge voltage6 kV
InsulationSafe isolation, basic insulation, and 4 kV rated surge voltage between all changeover contacts.
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Articles in set

Classifications


ETIM for 1049232 Relays (EC001437)
Feature Name Feature Value
Type of electric connection (EF003961) Other
Complete with socket (EF003359) Yes
With detachable clamps (EF003340) No
With LED indication (EF005950) Yes
Rated control supply voltage AC 50 Hz (EF003978) 19.2 V
Rated control supply voltage AC 60 Hz (EF003979) 19.2 V
Voltage type for actuating (EF008242) AC
Drive, polarization (EF003355) Polarized
Drive, switching attitude (EF003356) Mono stable
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Type of switch contact (EF003358) Single contact
With forced-guided contacts (EF003357) No
Material of contact insert (EF008521) Other
Material of contact surface (EF004020) Untreated
Nominal current (EF000001) 0.032 A
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 16 mm
Height (EF000040) 96 mm
Depth (EF000049) 75 mm