View larger
IBS RBC METER/E-T
2723149
PHOENIX CONTACT
1 m.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product type | Remote bus cable |
| Number of positions | 6 |
| Transmission medium | Copper |
| Number of positions | 6 |
| Shielded | yes |
| Conductor structure | 3 x 2 x 0.22 mm² |
| Signal speed | 0.66 c |
| Conductor structure signal line | 7x 0.20 mm |
| Conductor cross section | 3x 2x 0.22 mm² |
| External cable diameter | 9.00 mm |
| Outer sheath, material | PVC |
| External sheath, color | black RAL 9005 |
| Conductor material | Bare Cu litz wires |
| Material wire insulation | PE |
| Single wire, color | green-yellow, white-brown, gray-pink |
| Twisted pairs | 2 cores to the pair |
| Overall twist | 3 pairs to the core |
| Insulation resistance | ≥ 5 GΩ*km |
| Coupling resistance | < 250.00 mΩ/m (at 30 MHz) |
| Loop resistance | ≤ 186.00 Ω/km |
| Wave impedance | 120 Ω ±20 % (at 64 kHz) |
| 100 Ω ±15 % (with 1 MHz) | |
| Cable capacity | ≤ 60 nF/km (At 800 Hz) |
| Nominal voltage, cable | 250 V (Peak value, not for high-power applications) |
| Test voltage Core/Core | 1500 Vrms |
| Test voltage Core/Shield | 1000.00 Vrms |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 15 x D |
| Smallest bending radius, fixed installation | 68 mm |
| Smallest bending radius, movable installation | 135 mm |
| Near end crosstalk attenuation (NEXT) | ≥ 61 dB (at 772 kHz) |
| ≥ 59 dB (with 1 MHz) | |
| ≥ 55 dB (at 2 МHz) | |
| ≥ 50 dB (at 4 МHz) | |
| ≥ 46 dB (at 8 МHz) | |
| ≥ 44 dB (at 10 MHz) | |
| ≥ 41 dB (at 16 MHz) | |
| ≥ 40 dB (at 20 МHz) | |
| Shield attenuation | ≤ 15 dB/km (at 256 kHz) |
| ≤ 24 dB/km (at 772 kHz) | |
| ≤ 27 dB/km (with 1 MHz) | |
| ≤ 52 dB/km (at 4 МHz) | |
| ≤ 84 dB/km (at 10 MHz) | |
| ≤ 112 dB/km (at 16 MHz) | |
| ≤ 119 dB/km (at 20 МHz) | |
| Ambient temperature (operation) | -30 °C ... 70 °C (cable, fixed installation) |
| -5 °C ... 70 °C (Cable, flexible installation) |
| Feature Name | Feature Value |
|---|---|
| Conductor surface (EF010804) | Other |
| Nominal cross section conductor (EF000060) | 0.22 mm² |
| Conductor category (EF001632) | Class 2 = stranded |
| Number of cores (EF001792) | 6 |
| Material core insulation (EF000061) | Other |
| Specification core insulation (EF011805) | Polyethylene (PE) |
| Core identification (EF000067) | Other |
| Screen over stranding element (EF001623) | Braiding |
| Stranding (EF003802) | Other |
| Longitudinal water blocking cable (EF011011) | No |
| Radial water blocking cable (EF011012) | No |
| Suitable for underground installation (EF003689) | No |
| Protective sheath (EF001691) | None |
| Material outer sheath (EF001625) | Polyvinyl chloride (PVC) |
| Specification material outer sheath (EF011806) | Other |
| Colour outer sheath (EF001618) | Other |
| Low smoke according to EN IEC 61034-2 (EF003799) | No |
| Oil resistant according to EN IEC 60811-404 (EF009770) | No |
| Outer diameter approx. (EF003921) | 9 mm |
| Min. permitted bending radius, moving application/free movement (EF011802) | 135 mm |
| Min. permitted bending radius, stationary application/permanent installation (EF011803) | 68 mm |
| Permitted cable outer temperature during assembling/handling (EF001685) | -5 °C |
| Permitted cable outer temperature after assembling without vibration (EF001686) | -30 °C |
| Category (EF001619) | Other |