View larger
EMG 17-REL/KSR-48/21-21-LC
2940401
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2940401 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 135 (IF-2011) |
| GTIN | 4017918080075 |
| Weight per Piece (excluding packing) | 56.730 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Ambient temperature (operation) | -20 °C ... 40 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Nominal input voltage UN | 48 V AC/DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.1 |
| Typical input current at UN | 10 mA |
| Typical response time | 8 ms |
| Typical release time | 10 ms |
| Protective circuit | Bridge rectifier Bridge rectifier |
| Operating voltage display | Yellow LED |
| Power dissipation for nominal condition | 0.48 W |
| Contact type | Single contact, 2-PDT |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Maximum inrush current | 6 A |
| Limiting continuous current | 5 A |
| Interrupting rating (ohmic load) max. | 120 W (at 24 V DC) |
| 95 W (at 48 V DC) | |
| 60 W (at 60 V DC) | |
| 40 W (at 110 V DC) | |
| 55 W (at 220 V DC) | |
| 1250 VA (for 250 V AC) |
| Test voltage relay winding/relay contact | 4 kV AC (50 Hz, 1 min.) |
|---|---|
| Test voltage relay contact/relay contact | 1 kV AC (50 Hz, 1 min.) |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 5x 107cycles |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Net weight (SAP) | 56.73 g |
| Connection name | Coil side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Connection name | Contact side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Connection in acc. with standard | CUL |
|---|---|
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | EN 50178 |
| Rated insulation voltage | 260 V AC |
| Rated surge voltage | 2.3 kV |
| Insulation | Basic insulation |
| Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths | |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Designation | Air clearances and creepage distances between input and contact circuit (or output contact current path) |
| Standards/regulations | EN 50178 |
| Rated insulation voltage | 260 V AC |
| Rated surge voltage | 6 kV |
| Insulation | Safe isolation, reinforced insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Designation | Standards/regulations |
| Standards/regulations | EN 61810-1 |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |