EMG 10-REL/KSR-230/ 1-LC AU
2964416
PHOENIX CONTACT
10 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2964416 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 133 (IF-2011) |
| GTIN | 4017918107475 |
| Weight per Piece (excluding packing) | 36.000 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Ambient temperature (operation) | -20 °C ... 40 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Nominal input voltage UN | 230 V AC/DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.1 |
| Typical input current at UN | 4.8 mA |
| Typical response time | 7 ms |
| Typical release time | 11 ms |
| Protective circuit | Bridge rectifier Bridge rectifier |
| Surge protection Varistor | |
| Operating voltage display | Yellow LED |
| Power dissipation for nominal condition | 1.1 W |
| Contact type | Double contact, 1 N/O contact |
|---|---|
| Type of switch contact | Double contact |
| Contact material | AgPd60, hard gold-plated |
| Maximum switching voltage | 30 V AC |
| 36 V DC | |
| Minimum switching voltage | 100 µV |
| Min. switching current | 20 µA |
| Maximum inrush current | 0.2 A |
| Limiting continuous current | 0.5 A |
| Interrupting rating (ohmic load) max. | 5 W (at 24 V DC) |
| Note | the following values are applicable if a gold layer is destroyed |
|---|---|
| Maximum switching voltage | 125 V AC |
| 150 V DC | |
| Limiting continuous current | 2 A |
| Maximum inrush current | 2 A |
| Interrupting rating (ohmic load) max. | 29 W (at 24 V DC) |
| 29 W (at 48 V DC) | |
| 29 W (at 60 V DC) |
| Test voltage relay winding/relay contact | 4 kV AC (50 Hz, 1 min.) |
|---|---|
| Operating mode | 100% operating factor |
| Degree of protection | IP20 |
| Mechanical service life | approx. 2x 107cycles |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Net weight (SAP) | 36 g |
| Connection name | Coil side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Connection name | Contact side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Connection in acc. with standard | CUL |
|---|---|
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Rated insulation voltage | 260 V AC |
| Rated surge voltage | 4 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |