Safety relay with forced conduction contacts according to DIN EN 61810-3, contact switching type 2 switches. The requirements for type A according to DIN EN 61810-3 are met if the connection is made as 1 normally open contact/1 normally closed contact. Safety relay with force-guided contacts in accordance with DIN EN 61810-3, contact switching type: 2 changeover contacts. The requirements for type A in accordance with DIN EN 61810-3 are satisfied if the circuit is designed as 1 N/O contact / 1 N/C contact.

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralThe outputs are not suitable for switching different outer conductors.
GeneralAt least a basic level of insulation is maintained against adjacent modules in the DIN rail direction. If the application has higher requirements on the insulation (reinforced insulation), then these must be realized through suitable measures (e.g. partition plates).

Product properties
Product typeSingle relay
ApplicationForcibly guided contacts
Operating mode100% operating factor
Mechanical service lifeapprox. 107cycles
Insulation characteristics: Air clearances and creepage distances between the power circuits
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree2
Insulation characteristics: Air clearances and creepage distances between coil and contact side
InsulationReinforced insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties
Maximum power dissipation for nominal condition0.7 W
Test voltage (Winding/contact)4 kVrms(50 Hz, 1 min.)
Test voltage ()1.5 kVrms(50 Hz, 1 min.)
Test voltage (Changeover contact/changeover contact)2.5 kVrms(50 Hz, 1 min.)
Air clearances and creepage distances between the power circuits
Rated insulation voltage250 V AC
Rated surge voltage4 kV
Air clearances and creepage distances between coil and contact side
Rated insulation voltage250 V AC
Rated surge voltage6 kV

Input data
Coil side
Nominal input voltage UN24 V DC
Input voltage range19.2 V DC ... 26.4 V DC
Input voltage range in reference to UNsee diagram
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN30 mA
Input power dissipation for UN0.72 W
Typical response time15 ms
Typical release time10 ms
Coil voltage24 V DC
Protective circuitFreewheeling diode
Status displayYellow LED

Output data
Switching
Contact switching type2 changeover contacts, forcibly actuated
Type of switch contactSingle contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC
Limiting continuous current6 A
Interrupting rating (ohmic load) max.144 W (24 V DC)
58 W (48 V DC)
60 V DC
54 W (110 V DC)
55 W (220 V DC)
1500 VA (250 V AC)
Force-guided contacts in accordance with EN 61810-3Type B

Connection data
Cross section AWG(converted acc. to IEC)

Dimensions
Width12.6 mm
Height29 mm
Depth26.3 mm

Environmental and real-life conditions
Ambient conditions
Degree of protection (Relay)RT II (Relay)
Degree of protection (Installation location)IP54 (Installation location)
Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Altitude≤ 2000 m

Standards and regulations
Standards/regulationsEN 61810-1
EN 61810-3
Air clearances and creepage distances between the power circuits
Standards/regulationsEN 60947-5-1
Air clearances and creepage distances between coil and contact side
Standards/regulationsEN 60947-5-1

Mounting
Mounting typePlug-in mounting
Assembly instructionsin rows with zero spacing
Mounting positionany

ETIM for 1473564 Relays (EC001437)
Feature Name Feature Value
Complete with socket (EF003359) No
With detachable clamps (EF003340) No
With LED indication (EF005950) Yes
Rated control supply voltage DC (EF003980) 19.2 V
Voltage type for actuating (EF008242) DC
Drive, polarization (EF003355) Polarity free
Drive, switching attitude (EF003356) Mono stable
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Type of switch contact (EF003358) Single contact
With forced-guided contacts (EF003357) Yes
Material of contact insert (EF008521) Other
Material of contact surface (EF004020) Untreated
Nominal current (EF000001) 0.03 A
Degree of protection (IP) (EF005474) Other
Width (EF000008) 12.6 mm
Height (EF000040) 29 mm
Depth (EF000049) 26.3 mm