PHOENIX CONTACT QUINT4-PS/3AC/24DC/20/KONF1 QUINT4-PS/3AC/24DC/20/KONF1 1035480 PHOENIX CONTACT Power supply unit QUINT4-PS/3AC/24DC/20/KONF1 1035480 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

QUINT4-PS/3AC/24DC/20/KONF1 1035480 PHOENIX CONTACT Power supply unit QUINT4-PS/3AC/24DC/20/KONF1 1035480

QUINT4-PS/3AC/24DC/20/KONF1

1035480

PHOENIX CONTACT

1 Pcs.

Power supply unit - QUINT4-PS/3AC/24DC/20/KONF1 - 1035480 Pre-configured variant of the QUINT POWER primary-switched power supply for rail mounting, with optional output characteristic curve and SFB Technology (Selective Fuse Breaking), input: three-phase, Output: 24 V DC / 20 A

Automation > DC-power supply
Power Supplies (PS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Preconfigured version of the primary-switched QUINT POWER power supply for DIN rail mounting with free choice of output characteristic curve and SFB (Selective Fuse Breaking) Technology, input: 3-phase,
output: 24 V DC / 20 A

Key Commercial Data

Orderkey1035480
Packing unit1
GTIN4055626541846
Custom tariff number85044030

Dimensions

Width70 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly73 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-40 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 5000 m (> 2000 m, observe derating)

Input data

Nominal input voltage range3x 400 V AC ... 500 V AC
2x 400 V AC ... 500 V AC
± 260 V DC ... 300 V DC
Input voltage range3x 400 V AC ... 500 V AC -20 % ... +10 %
2x 400 V AC ... 500 V AC -10 % ... +10 %
± 260 V DC ... 300 V DC -13 % ... +30 %
AC frequency range50 Hz ... 60 Hz -10 % ... +10 %
Discharge current to PE< 3.5 mA
Current consumption3x 0.99 A (400 V AC)
3x 0.81 A (480 V AC)
2x 1.62 A (400 V AC)
2x 1.37 A (480 V AC)
3x 0.8 A (500 V AC)
2x 1.23 A (500 V AC)
Nominal power consumption541 VA
Inrush currenttyp. 2 A (at 25 °C)
Mains buffering time≥ 25 ms (3x 400 V AC)
≥ 25 ms (3x 480 V AC)
Choice of suitable circuit breakers3x 4 A ... 20 A (Characteristic B, C or comparable)
Type of protectionTransient surge protection
Protective circuit/componentVaristor, gas-filled surge arrester

Output data

Nominal output voltage26 V DC
Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (constant capacity)
Nominal output current (IN)20 A
Static Boost (IStat.Boost)25 A
Dynamic Boost (IDyn.Boost)30 A (5 s)
Selective Fuse Breaking (ISFB)120 A (15 ms)
Derating> 60 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistance≤ 35 V DC
Output overvoltage protection≤ 32 V DC
Control deviation< 0.5 % (Static load change 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.25 % (change in input voltage ±10 %)
Residual ripple< 60 mVPP(with nominal values)
Output power480 W
Typical response time300 ms (from SLEEP MODE)
Maximum power dissipation in no-load condition< 7 W (400 V AC)
< 7 W (480 V AC)
Power loss nominal load max.< 32 W (400 V AC)
< 33 W (480 V AC)

General

Net weight1.1 kg
Efficiencytyp. 93.9 % (400 V AC)
typ. 93.8 % (480 V AC)
Insulation voltage input/output4 kV AC (type test)
2.4 kV AC (routine test)
Insulation voltage input / PE3.5 kV AC (type test)
2.4 kV AC (routine test)
Insulation voltage output / PE0.5 kV DC (type test)
0.5 kV DC (routine test)
Protection classI
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 985000 h (25 °C)
> 638000 h (40 °C)
> 311000 h (60 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.30
Conductor cross section AWG max.10
Stripping length8 mm

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.6 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.30
Conductor cross section AWG max.10
Stripping length8 mm

Connection data for signaling

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise immunityImmunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply)
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m (Test Level 2)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
Conducted noise emissionEN 55016 EN 61000-6-4 (Class A)
Standards/regulationsEN 61000-4-8
EN 61000-4-11
EN 61000-4-9
EN 61000-4-12
EN 61000-4-16
EN 61000-4-18
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)
Standard - power supply devices for low voltage with DC outputEN 61204-3
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Shipbuilding approvalDNV GL, PRS, BV, LR, ABS
UL approvalsUL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
Approval - requirement of the semiconductor industry with regard to mains voltage dipsSEMI F47-0706; EN 61000-4-11
Rail applicationsEN 50121-3-2
Overvoltage category (EN 60950-1)II
Overvoltage category (EN 61010-1)II
Overvoltage category (EN 62477-1)III

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Classifications

eCl@ss

eCl@ss 6.027049000
eCl@ss 7.027049002
eCl@ss 8.027049002
eCl@ss 9.027040701

ETIM

ETIM 6.0EC002540
ETIM 7.0EC002540

ETIM for 1035480 Low-voltage industrial controls and switchgear (EC002540)
Feature Name Feature Value
Voltage type (supply voltage) (EF002991) AC/DC
1st secondary output voltage (EF006792) 24 V
Max. output current 1 (EF008284) 30 A
Secondary voltage adjustable (EF007002) Yes
Nominal value output voltage 1 (EF009393) 26 V
Nominal value output current 1 (EF009396) 20 A
Short-circuit-proof (EF007332) Yes
Rated supply voltage AC 50 Hz (EF007076) 400 V
Rated supply voltage AC 60 Hz (EF007077) 400 V
Rated supply voltage DC (EF007078) 260 V
Output voltage stabilized (EF003092) Yes
Power consumption (EF000346) 541 VA
Power output (EF003034) 480 W
Stabilized (EF005302) Yes
Type of electric connection (EF003961) Screw connection
Suitable for rail mounting (EF003972) Yes
Wall mounting possible (EF003973) No
Modular version (EF001126) No
Built-in height (EF000332) 130 mm
Direct mounting possible (EF005689) No
Width (EF000008) 70 mm
Height (EF000040) 130 mm
Depth (EF000049) 125 mm
Suitable for safety functions (EF001597) Yes
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.