PHOENIX CONTACT QUINT4-PS/1AC/12DC/2.5/PT QUINT4-PS/1AC/12DC/2.5/PT 2904605 PHOENIX CONTACT Primary-switched power supply unit, QUINT POWER, Push-in c.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

QUINT4-PS/1AC/12DC/2.5/PT 2904605 PHOENIX CONTACT Primary-switched power supply unit, QUINT POWER, Push-in c..

QUINT4-PS/1AC/12DC/2.5/PT

2904605

PHOENIX CONTACT

1 Pcs.

Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 2.5 A Primary switching power supplies, QUINT POWER, Push-in connection, Rail mounting, input:1phase, output: 12 VDC / 2.5 A

Automation > DC-power supply
Power Supplies (PS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2904605
Packing unit1 pc
Catalog pagePage 252 (C-4-2019)
GTIN4055626255736
Weight per Piece (excluding packing)240.000 g
Custom tariff number85044030
Country of originDE (Germany)

Drawings



Block diagram

Block diagram

Diagram

Diagram



Diagram

Diagram

Diagram

Diagram



Schematic diagram

Schematic diagram

Back to top

Dimensions

Width22.5 mm
Height106 mm
Depth90 mm
Back to top

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 5000 m (> 2000 m, observe derating)
Back to top

Input data

Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
110 V DC ... 250 V DC -20 % ... +40 %
Dielectric strength maximum300 V AC 60 s
Frequency range (fN)50 Hz ... 60 Hz -10 % ... +10 %
Discharge current to PE< 0.25 mA (264 V AC, 60 Hz)
Current consumption0.44 A (100 V AC)
0.35 A (120 V AC)
0.19 A (230 V AC)
0.2 A (240 V AC)
Nominal power consumption32.8 VA
Inrush currenttyp. 11.3 A (at 25 °C)
Mains buffering timetyp. 54 ms (120 V AC)
typ. 54 ms (230 V AC)
Input fuse3.15 A (slow-blow, internal)
Recommended breaker for input protection6 A ... 16 A (Characteristic B, C or comparable)
Type of protectionTransient surge protection
Protective circuit/componentVaristor
Back to top

Output data

Nominal output voltage12 V DC
Setting range of the output voltage (USet)12 V DC ... 15 V DC (constant capacity)
Nominal output current (IN)2.5 A
Static Boost (IStat.Boost)3.125 A (≤ 40 °C)
Dynamic Boost (IDyn.Boost)4.5 A (≤ 60 °C (5 s))
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback voltage resistance≤ 25 V DC
Protection against overvoltage at the output (OVP)≤ 18 V DC
Control deviation< 0.2 % (Static load change 10 % ... 90 %)
< 2 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 30 mVPP(with nominal values)
Output power30 W
Typical response time500 ms
Maximum power dissipation in no-load condition< 0.4 W (230 V AC)
< 0.5 W (120 V AC)
Power loss nominal load max.< 3.5 W (120 V AC)
< 3 W (230 V AC)
Back to top

General

Net weight0.181 kg
Efficiencytyp. 89.5 % (120 V AC)
typ. 90.9 % (230 V AC)
Insulation voltage input/output4 kV AC (type test)
3 kV AC (routine test)
Protection classII
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 1848000 h (25 °C)
> 1060000 h (40 °C)
> 459000 h (60 °C)
Back to top

Connection data, input

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm
Back to top

Connection data, output

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm
Back to top

Connection data for signaling

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length10 mm
Back to top

Standards

Standard - Safety of transformersEN 61558-2-16
Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1
Standard – Safety extra-low voltageIEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolationIEC 61558-2-16
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Back to top

Conformance/approvals

UL approvalsUL Listed UL 61010-1
UL Listed UL 61010-2-201
UL 1310 Class 2 Power Units
ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
SIQCB-Scheme (IEC 61010-1, IEC 61010-2-201)
Back to top

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
EN 61000-6-3 (Class B)
Noise emissionEN 55016
EN 61000-6-3 (Class B)
Harmonic currentsEN 61000-3-2
EN 61000-3-2 (Class A)
FlickerEN 61000-3-3
Electrostatic dischargeEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength20 V/m (Test Level X)
Frequency range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output4 kV (Test Level X - asymmetrical)
Signal4 kV (Test Level X - asymmetrical)
CommentsCriterion A
Surge voltage load (surge)EN 61000-4-5
Input2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal0.5 kV (Test Level 2 - symmetrical)
CommentsCriterion A
I/O/Sasymmetrical
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
CommentsCriterion A
Frequency16.67 Hz
50 Hz
60 Hz
Test field strength100 A/m
Additional text60 s
CommentsCriterion A
Frequency50 Hz
60 Hz
Test field strength1 kA/m
Additional text3 s
Frequency0 Hz
Test field strength300 A/m
Additional textDC, 60 s
Voltage dipsEN 61000-4-11
Voltage100 V AC
Frequency60 Hz
Voltage dip70 %
Number of periods0.5 / 1 / 30 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Number of periods5 / 10 / 50 periods
Additional textTest Level 2
CommentsCriterion B
Voltage dip0 %
Number of periods0.5 / 1 / 5 / 50 periods
Additional textTest Level 2
CommentsCriterion B
Pulse-shape magnetic fieldEN 61000-4-9
Test field strength1000 A/m
CommentsCriterion A
Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12
Input2 kV (symmetrical)
4 kV (asymmetrical)
CommentsCriterion A
Asymmetrical conducted disturbance variablesEN 61000-4-16
Test level 116.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Voltage30 V (10 s)
Test level 216.67 Hz 50 Hz 60 Hz (Test Level 2)
Voltage300 V (1 s)
CommentsCriterion A
Attenuated oscillating waveEN 61000-4-18
Voltage1 kV (symmetrical)
2.5 kV (asymmetrical)
1 kV (symmetrical)
CommentsCriterion A
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Back to top

Classifications

eCl@ss

eCl@ss 5.127242213
eCl@ss 6.027049000
eCl@ss 7.027049002
eCl@ss 8.027049002
eCl@ss 9.027040701
Back to top

ETIM

ETIM 5.0EC002540
ETIM 6.0EC002540
ETIM 7.0EC002540
Back to top

UNSPSC

UNSPSC 13.239121004
UNSPSC 18.039121004
UNSPSC 19.039121004
UNSPSC 20.039121004
UNSPSC 21.039121004
Back to top

ETIM for 2904605 Low-voltage industrial controls and switchgear (EC002540)
Feature Name Feature Value
Voltage type (supply voltage) (EF002991) AC/DC
1st secondary output voltage (EF006792) 12 V
Max. output current 1 (EF008284) 4.5 A
Secondary voltage adjustable (EF007002) Yes
Nominal value output voltage 1 (EF009393) 12 V
Nominal value output current 1 (EF009396) 2.5 A
Short-circuit-proof (EF007332) Yes
Rated supply voltage AC 50 Hz (EF007076) 100 V
Rated supply voltage AC 60 Hz (EF007077) 100 V
Rated supply voltage DC (EF007078) 110 V
Output voltage stabilized (EF003092) Yes
Power consumption (EF000346) 32.8 VA
Power output (EF003034) 30 W
Stabilized (EF005302) Yes
Type of electric connection (EF003961) Other
Suitable for rail mounting (EF003972) Yes
Wall mounting possible (EF003973) No
Modular version (EF001126) No
Built-in height (EF000332) 106 mm
Direct mounting possible (EF005689) No
Width (EF000008) 22.5 mm
Height (EF000040) 106 mm
Depth (EF000049) 90 mm
Suitable for safety functions (EF001597) Yes
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.